Pathways to a Smarter Power System 2019
DOI: 10.1016/b978-0-08-102592-5.00011-9
|View full text |Cite
|
Sign up to set email alerts
|

New Protection Schemes in Smarter Power Grids With Higher Penetration of Renewable Energy Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(9 citation statements)
references
References 33 publications
0
9
0
Order By: Relevance
“…PMUs are used to produce synchrophasor measurementsfundamental frequency voltage and current measurements that are time synchronised [54]. Normally, synchophasors are communicated to a central computer, and this information can be used to undertake state estimation, fault detection/location and wide area monitoring, including protection [55]- [57]. While the use of synchrophasors from multiple PMUs can be used to measure line impedance [51], [58], [59], the focus of this article is on the local techniques which utilise local measurements only.…”
Section: ) Local Pmu Derived Observersmentioning
confidence: 99%
“…PMUs are used to produce synchrophasor measurementsfundamental frequency voltage and current measurements that are time synchronised [54]. Normally, synchophasors are communicated to a central computer, and this information can be used to undertake state estimation, fault detection/location and wide area monitoring, including protection [55]- [57]. While the use of synchrophasors from multiple PMUs can be used to measure line impedance [51], [58], [59], the focus of this article is on the local techniques which utilise local measurements only.…”
Section: ) Local Pmu Derived Observersmentioning
confidence: 99%
“…where; I A is the local-end current; I B is the remote-end current Power flow is normally unidirectional from the source to consumers [18][19][20] with conventional generators. However, lately there is an overwhelming RE penetration such as solar PV in power system [19][20][21][22].…”
Section: Line Differential Protection Relaymentioning
confidence: 99%
“…As a result, it is a challenge to power system protection since most of the protective relaying design is based on the assumption which is radial in nature. Therefore, due to the impact of RE to power system behavior [17][18][19][20][21][23][24][25], the reliability of differential protection scheme needs be analyzed when the power system network is without and with RE penetration such as solar PV.…”
Section: Line Differential Protection Relaymentioning
confidence: 99%
“…Many researchers have conducted studies on how to maintain the availability of electricity [1,2,3,4]. Likewise, to maintain the system security from various kinds of interference [5,6,7], in order that the sustainability of electricity supply to consumers can be enhanced. To increase the consumers' electricity supply, the producers are required to add the power supply to the system.…”
Section: Introductionmentioning
confidence: 99%