2018
DOI: 10.1155/2018/3589762
|View full text |Cite
|
Sign up to set email alerts
|

New Optic Nerve Sonography Quality Criteria in the Diagnostic Evaluation of Traumatic Brain Injury

Abstract: Background New sonographic quality criteria to optimize optic nerve sheath diameter (ONSD) measurements were suggested. The latter were correlated to elevated intracranial pressure (ICP) in traumatic brain injury (TBI). Aim We investigated whether ONSD measurements were correlated to simultaneous ICP measurements in severe TBI. Methods Forty patients with severe TBI (Marshall Scale ≥II and GCS ≤8) participated in the study. All patients had an intraparenchymal ICP catheter inserted, while ONSD was measured bil… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
40
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 26 publications
(43 citation statements)
references
References 29 publications
2
40
0
1
Order By: Relevance
“…31 Early data suggest that these criteria may lead to a change in normal values for ONSD measurement. 9 These criteria emphasize bilateral ocular sonography and avoidance or identification of landmarks within and around the globe, which are not simulated in our model. To our knowledge, no model to date has been developed which is able to simulate all structures necessary to apply the new quality criteria.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…31 Early data suggest that these criteria may lead to a change in normal values for ONSD measurement. 9 These criteria emphasize bilateral ocular sonography and avoidance or identification of landmarks within and around the globe, which are not simulated in our model. To our knowledge, no model to date has been developed which is able to simulate all structures necessary to apply the new quality criteria.…”
Section: Discussionmentioning
confidence: 99%
“…This black line is the optic nerve, and its diameter is measured 3 mm behind the optic disc (Figure 3). [7][8][9]22,23 Measurements were conducted by three expert point-of-care ultrasonographers (LG, TJ, AD) in a single session. The diameters were 3.5 mm (polyvinyl intravenous line tubing), 4 mm (nasogastric tube), 4.2 mm (spring wire guide sheath), 4.6 mm (nasogastric tube), 5.5 mm (nasogastric tube), 6 mm (tracheostomy cannula), and 7.9 mm (nasogastric tube).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The ONSD measurement was performed according to the new Optic Nerve Sonography Quality Criteria. [8]. While recording proper images for measurement, we considered the following matters: clear discrimination of optic nerve, internal and external border of the subarachnoid space; capturing close proximity of the hypoechogenic regions which belong to optic nerve fibers and vitreous fluid inside the eye globe and lens-free images.…”
Section: Measurement Techniquementioning
confidence: 99%
“…Optic nerve sheath is anatomically continuous with dura mater, and optic nerve, pia mater and subarachnoid space can be distinguished easily with proper technique [7]. Ultrasonographic images should be obtained with appropriate techniques according to new Optic Nerve Sonography Quality Criteria [8]. Recent studies suggest that daily monitoring of ONSD measurement by USG can be useful not only for the determination of increased ICP but also for evaluating the neurological prognosis of the patients [9][10][11].…”
Section: Introductionmentioning
confidence: 99%