New microangiography system development providing improved small vessel imaging, increased contrast-to-noise ratios, and multiview 3D reconstructions

Abstract: A new microangiographic system (MA) integrated into a c-arm gantry has been developed allowing precise placement of a MA at the exact same angle as the standard x-ray image intensifier (II) with unchanged source and object position. The MA can also be arbitrarily moved about the object and easily moved into the field of view (FOV) in front of the lower resolution II when higher resolution angiographic sequences are needed. The benefits of this new system are illustrated in a neurovascular study, where a rabbit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2006
2006
2009
2009

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…There may be occasions, due to the physical spacing, between the imaging detector and the object, being limited when that a full dataset of 360° may not be possible. In this kind of situation, micro-CBCT may not be possible but the MVR technique may be done since it uses only 3 projections [25].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…There may be occasions, due to the physical spacing, between the imaging detector and the object, being limited when that a full dataset of 360° may not be possible. In this kind of situation, micro-CBCT may not be possible but the MVR technique may be done since it uses only 3 projections [25].…”
Section: Resultsmentioning
confidence: 99%
“…The pixel size of the XII is 120 μm, and FOV is 4.5 in. The same projections were also obtained using the MA support system assembled on the x-ray unit [25]. The support system enables us the facility to obtain the projections at the same orientation using the XII and the MA, without moving the object and the source.…”
Section: Mvr Data Acquisitionmentioning
confidence: 99%
“…A schematic of the SSXII prototype module is shown in figure 1. The imaging components are packaged in a light-tight enclosure which can be mounted on a clinical c-arm gantry for combined large field-of-view (FOV) low-resolution imaging with a FPD and high-resolution region-of-interest (ROI) imaging with the SSXII14, 15.…”
Section: Methodsmentioning
confidence: 99%
“…The improved EIGI methods [1,2,3,4] along with the new x-ray imaging detectors [5,6,7,8] are essential tools for the treatment of cerebrovascular diseases (CVD) [3] such as aneurysms and vessel stenoses. Furthermore, improved design of software that automates the radiographic procedures for the above methods and simplifies the job of the radiologist or interventionalist is important for better treatment and more accurate diagnoses.…”
Section: Introductionmentioning
confidence: 99%