IEEE International Workshop on Intelligent Signal Processing, 2005.
DOI: 10.1109/wisp.2005.1531688
|View full text |Cite
|
Sign up to set email alerts
|

New methods for precise detection of systolic complexes in the signal acquired from quantitative seismocardiograph

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0
1

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(9 citation statements)
references
References 3 publications
0
8
0
1
Order By: Relevance
“…The range of wavelet signals on the sixth scale (CD6) is 7.8125~15.625Hz by sampled at 500Hz, as TABLE 1 shows. It can be concluded that the frequency range of BCG is around 10Hz from Figure3 which shows ED of original BCG [7]. Therefore, CD6 could be extracted directly as actual timedomain BCG.…”
Section: Results Of Experiments and Simulationmentioning
confidence: 98%
“…The range of wavelet signals on the sixth scale (CD6) is 7.8125~15.625Hz by sampled at 500Hz, as TABLE 1 shows. It can be concluded that the frequency range of BCG is around 10Hz from Figure3 which shows ED of original BCG [7]. Therefore, CD6 could be extracted directly as actual timedomain BCG.…”
Section: Results Of Experiments and Simulationmentioning
confidence: 98%
“…Una vez hecho esto se realzan las oscilaciones debidas a la actividad cardiaca filtrando pasa banda el BCG con frecuencias de corte de 3 Hz y 10 Hz. Posteriormente, se eleva el BCG a la tercera potencia, para conservar la polaridad de la señal y realzar las oscilaciones principales [22], aplicando ventanas temporales con duración de 1,2 s, que es suficientemente larga para incluir frecuencias cardiacas bajas.…”
Section: Pre-procesamiento Digital Del Bcgunclassified
“…Past ballistocardiographs, for example [9] (pages [13][14][15][16][17][18], have used a chair in which whole of the body is supported by the chair, and the sensors record the movement of the whole chair unit.…”
Section: Bcg Measurementmentioning
confidence: 99%
“…The film-type sensor element and amplifier are quite similar to EMFi, but the obtained signal and proposed sleep-monitoring application have more similarities to SCSB sensor [8]. Other recent publications on BCG measurement have used piezoelectric transducers and accelerometer sensors [17], and even optical F seat F back fibers [18] to produce simple and inexpensive sensor solutions.…”
Section: Sensor Technology Related Workmentioning
confidence: 99%