2002
DOI: 10.1016/s0584-8547(02)00109-x
|View full text |Cite
|
Sign up to set email alerts
|

New methodical and instrumental developments in laser ablation inductively coupled plasma mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
31
0

Year Published

2003
2003
2010
2010

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(32 citation statements)
references
References 33 publications
1
31
0
Order By: Relevance
“…The simultaneous analysing mode of the ICP-TOF-MS leads to several advantages including (i) no limitation on the number of analysed isotopes and (ii) its analysis time when compared to other ICP-MS techniques. While the ICP-TOF-MS system needs 1.5 minutes per sample to analyse the mass range from 7 Li to 238 U (6-fold analysis, 175000 sweeps), the ICP-Q-MS needs 7 minutes for 40 isotopes …”
Section: Concentrations In Antarctic Ice Core Samplesmentioning
confidence: 99%
“…The simultaneous analysing mode of the ICP-TOF-MS leads to several advantages including (i) no limitation on the number of analysed isotopes and (ii) its analysis time when compared to other ICP-MS techniques. While the ICP-TOF-MS system needs 1.5 minutes per sample to analyse the mass range from 7 Li to 238 U (6-fold analysis, 175000 sweeps), the ICP-Q-MS needs 7 minutes for 40 isotopes …”
Section: Concentrations In Antarctic Ice Core Samplesmentioning
confidence: 99%
“…Consequently, using Al/Fe and Ti/Fe ratio signals (providing that the Fe signals are those which would correspond to a 100% of this element), the values from beads and from steel samples, with similar Al or Ti content, should be comparables. Then, the calibration graphs, for Al and Ti determination in steel samples, can be constructed by normalizing the 27 Al and 48 Ti signals of the glass samples to the signal that would correspond to a 100% of Fe. The obtained plots, from the beads samples listed in Table 3, are depicted in Fig.…”
Section: Calibration Graphsmentioning
confidence: 99%
“…Aeschliman et al [26] used analyte signals from desolvated particles for a two-point calibration method, measuring online the transport of sample particulates from the ablation cell with a piezoelectric microbalance to provide signal normalization. Hoffmann et al [27] pointed out that the precision and accuracy of the results are influenced by signal standardization, calibration standards and the mass-spectrometric measuring mode. Sanborn and Telmer [28] showed that line scan mode provided some advantages over spot analysis, obviating some complications such as changes in ablation yield and element fractionation that occur with increasing pit depth and Gaussian pit morphology.…”
Section: Introductionmentioning
confidence: 99%
“…The investigations described here were performed using an in-house manufactured orthogonal acceleration time of flight-mass spectrometer [10]. A schematic outline of the ICP-TOF-MS instrument is presented in Fig.…”
Section: Icp-tof-ms Instrumentmentioning
confidence: 99%
“…By this way the velocity spread of ions will be reduced, both along and perpendicular to the flight tube, which results in small lines, better resolution and lower background. Based on this improvement an ICP-TOF-MS instrument has been developed and built up in our laboratory and used in the present study [10].…”
Section: Introductionmentioning
confidence: 99%