2020
DOI: 10.1097/j.jcrs.0000000000000165
|View full text |Cite
|
Sign up to set email alerts
|

New method to assess the accuracy of intraocular lens power calculation formulas according to ocular biometric parameters

Abstract: This query form must be returned with all proofs for corrections Please confirm the given names (pink) and surnames (blue) of authors have been identified correctly.Author Queries AU1) Please specify the exact years for clarity. AU2) The references should be sequentially cited in the text, hence references have been renumbered both in the text and in the reference list (including with tables, if present). Please check, and correct if necessary. AU3) Please provide the page range in reference 4. AU4) Please pro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 28 publications
0
8
0
Order By: Relevance
“… 2018 ; Fernández et al. 2020 ). Conversely, for eyes with biometric values that deviate from the average, accuracy can vary depending on the formulas (Gavin & Hammond 2008 ; Eom et al.…”
Section: Introductionmentioning
confidence: 99%
“… 2018 ; Fernández et al. 2020 ). Conversely, for eyes with biometric values that deviate from the average, accuracy can vary depending on the formulas (Gavin & Hammond 2008 ; Eom et al.…”
Section: Introductionmentioning
confidence: 99%
“…The relationships between the AXL and IOL power with the hyperopic shift suggest that this effect should be particularly investigated in future studies, putting special emphasis on short eyes implanted with a high IOL power for which the ALP variation can produce a higher change in SE than IOLs with a lower power. Although conclusions could not be made through the descriptive analysis of PE for several biometric parameters, our results also suggest that eyes with longer LT and bigger WTW should be further explored in future studies, having not previously been described for the Barrett formula [ 15 ]. On the other hand, in our study, the percentages of eyes in ± 0.50 D and ± 1.00 D after refraction stabilization were 67% and 90%, respectively.…”
Section: Discussionmentioning
confidence: 76%
“…The assessment of confounding factors as corneal power changes between 1 and 12 months was evaluated with the paired t -test. The influence of biometric parameters and PE was descriptively evaluated with plots previously described in the literature [ 15 ]. The association between PCO or Nd:YAG and PE changes was evaluated with the Fisher’s exact test.…”
Section: Methodsmentioning
confidence: 99%
“…This also allows the simple calculation of area using the trapezoidal rule. 15 Curvilinear regression (fitting a curve) finds a mathematical expression that produces a curved line to be the closest or exact fit to the measured data points, when the relationship between the variables is non-linear. 14 The validity of this curvilinear regression must be assessed statistically, and there are five main models that can be used to assess GOF.…”
Section: Introductionmentioning
confidence: 99%
“…Alternatively, a piecewise linear function can be fitted to the defocus curve data which, like a spline curve, is guaranteed to connect to all data points on the curve. This also allows the simple calculation of area using the trapezoidal rule 15 …”
Section: Introductionmentioning
confidence: 99%