New Measures of Power-Grid Voltage Variation

Abstract: This paper describes a new method of power-grid signal variation measurement, consisting of a demodulation algorithm and a set of measures (indices). The measures that will be presented are the abstract functionals, operating on the complex envelope of a signal. This paper presents a demodulation algorithm, definitions of proposed functionals, results of simulations, as well as laboratory experiments.Index Terms-Flicker, measures, power quality (PQ), signal processing, voltage variations.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 19 publications
0
4
0
Order By: Relevance
“…This can be achieved by averaging instantaneous frequency estimates with an averaging filter . The length of the filter has to be chosen in accordance with the dynamics of the frequency regulation process .…”
Section: The Proposed Methodsmentioning
confidence: 99%
“…This can be achieved by averaging instantaneous frequency estimates with an averaging filter . The length of the filter has to be chosen in accordance with the dynamics of the frequency regulation process .…”
Section: The Proposed Methodsmentioning
confidence: 99%
“…• modification of currently used measuring instruments [10]- [12], or use of other measures of voltage fluctuation severity assessment [13]- [16];…”
Section: Introductionmentioning
confidence: 99%
“…However, the existing indicators do not allow: unequivocal identification of the source of disturbance; and the assessment of its character, considering the psychophysical state of the observer of the obnoxious flicker and the operation of loads supplied from the same circuit as the source of the disturbance. The presented problem can be solved by recording the voltage signal and using: wavelet transform [8,9], Wigner-Ville transform [10], Hilbert transform [11,12], genetic algorithms [13], or the Kalman Filter [14]. However, at present these methods cannot be used in practical implementations due to the need to store a significant amount of data to implement these algorithms during continuous monitoring of the power grid.…”
Section: Introductionmentioning
confidence: 99%
“…• No modification of currently used measuring and recording devices in practice; • Implementation of the currently proposed signal analysis algorithms [8][9][10][11][12][13] for the recreated voltage envelope; load, e.g., about the frequency of changes in the state of the disturbance source [16].…”
Section: Introductionmentioning
confidence: 99%