1991
DOI: 10.1016/0924-4247(91)87084-g
|View full text |Cite
|
Sign up to set email alerts
|

New magnetoresistive sensors: Engineering and applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

1997
1997
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…The stripes are arranged such that the current flows through the NiFe layers are effectively orthogonal for adjacent arms of the Wheatstone bridge. This common technique has been extensively discussed in previous literature ( 64 , 65 ). The magnetic stripes are oriented orthogonally to the catheter axis, such that they roll up to form rings during the self-assembly ( Fig.…”
Section: Resultsmentioning
confidence: 99%
“…The stripes are arranged such that the current flows through the NiFe layers are effectively orthogonal for adjacent arms of the Wheatstone bridge. This common technique has been extensively discussed in previous literature ( 64 , 65 ). The magnetic stripes are oriented orthogonally to the catheter axis, such that they roll up to form rings during the self-assembly ( Fig.…”
Section: Resultsmentioning
confidence: 99%
“…[124] There are many types of magnetic sensors in geomagnetic field detection: for example, superconducting quantum interference devices, which require extremely low operational temperatures of liquid nitrogen in order to attain great sensitivity. [125] Fluxgate sensors [126] based on exciting coil/high permeability core have been investigated for many years to detect DC magnetic and geomagnetic fields. This widely used fluxgate sensor is relatively cheap and temperature-independent; however, its magnetic hysteresis, offset value under zero magnetic field, and large demagnetization factor restrict design considerations.…”
Section: Geomagnetic Interactionmentioning
confidence: 99%
“…For AMR sensors to detect the geomagnetic field, they must be geometrically conditioned to modify their intrinsic response, typically by using the barber pole method. [ 140–143 ] This method consists of stripes of ferromagnetic material, which are covered with slabs of a conductive material, oriented at 45° with respect to the long axis of the stripes. This modification forces the current to flow at 45° in the stripes, which effectively linearizes their AMR response around zero magnetic field.…”
Section: Geomagnetosensitive E‐skinsmentioning
confidence: 99%