2014
DOI: 10.1088/0004-637x/794/2/148
|View full text |Cite
|
Sign up to set email alerts
|

New Insights Into the Physical Nature of Coronal Mass Ejections and Associated Shock Waves Within the Framework of the Three-Dimensional Structure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

9
100
0
4

Year Published

2015
2015
2021
2021

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 90 publications
(115 citation statements)
references
References 48 publications
9
100
0
4
Order By: Relevance
“…The other source of the error is the 3D geometry of the shock modeled with the ellipsoid. The error of the ellipsoid model has been determined as shown in the Appendix of Kwon et al (2014). The error is ∼4% for all images we have analyzed.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The other source of the error is the 3D geometry of the shock modeled with the ellipsoid. The error of the ellipsoid model has been determined as shown in the Appendix of Kwon et al (2014). The error is ∼4% for all images we have analyzed.…”
Section: Resultsmentioning
confidence: 99%
“…We believe that this effect is negligible in the corona. Instead, we determine the error in the ellipsoid model as shown in the Appendix in Kwon et al (2014). This error gives us the difference of the ellipsoid model from the observed front.…”
Section: Error In Electron Density Excessmentioning
confidence: 99%
“…It can be a reasonable assumption in the low corona since the CME shock expansion is usually dominant in the initial phase of CME eruptions (e.g., Kwon et al 2014). The circular shock front propagates outward, with a constant expansion speed V sh =2000 km s −1 and a compression ratio X=3.…”
Section: Shock and Magnetic Fieldsmentioning
confidence: 99%
“…In particular, here we will use the compound geometric model developed by Kwon et al (2014) to determine the three-dimensional (3D) structure of the CME associated with the 2010 August 14 SEP event using EUV and WL data from STEREO-A, STEREO-B, SDO, and SOHO. An ellipsoid shape centered at a certain altitude h E is used to describe the outermost front driven by the CME.…”
Section: Cme Front Shockmentioning
confidence: 99%
“…The GCS model has seven free parameters: the height, longitude, and latitude of the center of the flux rope, as well as the half angle, aspect ratio, height, and rotation of the flux rope, as described in detail by Thernisien (2011). The ellipsoid model also uses seven free parameters: the height, longitude, and latitude of the center of the ellipsoid; the length of the three semi-principal axes; and rotation angle of the ellipsoid (see details in Kwon et al 2014).…”
Section: Cme Front Shockmentioning
confidence: 99%