2021
DOI: 10.1007/s12633-021-01049-9
|View full text |Cite
|
Sign up to set email alerts
|

New Improved Thermoluminescence Magnesium Silicate Material for Clinical Dosimetry

Abstract: Magnesium silicate has been prepared by a precipitation technique. This composite structure was proven by different tools, XRD, TGA&DTA, FTIR, and XRF. Magnesium silicate was found to have the formulas Mg1.1SiO3.2.1.1H2O. Thermoluminescence (TL) dosimetric properties like (linearity, fading, energy independence) of magnesium silicate in the shape of MgSiO3 have been estimated. A strong TL dosimetry peak associated with gamma radiation arises from 137 Cs was developed. Different doses from gamma radiation were … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1
1

Relationship

2
5

Authors

Journals

citations
Cited by 24 publications
(11 citation statements)
references
References 42 publications
0
11
0
Order By: Relevance
“…The bands appeared at 1040 & 905 cm -1 attributed to Si-O-Si & Si-O-H deformation vibration, respectively [27]. The bands at 636 & 460 cm -1 , attributed to Si-O [19].…”
Section: Ft-irmentioning
confidence: 98%
See 1 more Smart Citation
“…The bands appeared at 1040 & 905 cm -1 attributed to Si-O-Si & Si-O-H deformation vibration, respectively [27]. The bands at 636 & 460 cm -1 , attributed to Si-O [19].…”
Section: Ft-irmentioning
confidence: 98%
“…1). This Figure shows that broadband was noticed at 3470-3300 cm -1 due to H 2 O (stretching vibration) and OH adsorbed on {P(AN-AM)-NS} [19]. Two bands were noticed at 3190 & 2940 cm -1 due to N-H (stretching vibration) & CH 2 , respectively, [20][21][22].…”
Section: Ft-irmentioning
confidence: 99%
“…This decrease may be related to the reduction of the H2O content of metals by in-situ doping. At 1625 cm -1 , a strong band attributed to a bending vibration for water molecules absorbed on composites prepared [21,22]. At 1000 cm -1 due to Ti-OH deformation vibration [23], or overlapping of the Si-O and Si-OH [20], and Ti-O bonds in the structure, the band appeared at 780 cm -1 [24].…”
Section: Characterizationmentioning
confidence: 99%
“…Two bands at 567 and 480 cm -1 are assigned to Si-O-Ti and Si-O-Si (bending vibrations), respectively [24]. Bands at 416-465 cm -1 are associated with metal-O bonds (Co, Cd-O) [21].…”
Section: Characterizationmentioning
confidence: 99%
“…IR spectrum of {P(AN-AM)-NS} nanocomposite (Fig.1). This Figure shows that broadband was noticed at 3470-3300 cm -1 due to H 2 O (stretching vibration) and OH adsorbed on {P(AN-AM)-NS}[19]. Two bands were noticed at 3190 & 2940 cm -1 due to N-H (stretching vibration) & CH 2 , respectively,[20][21][22].…”
mentioning
confidence: 99%