2004
DOI: 10.1016/j.aca.2004.05.046
|View full text |Cite
|
Sign up to set email alerts
|

New flow-multicommutation method for the photo-chemiluminometric determination of the carbamate pesticide asulam

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0

Year Published

2006
2006
2020
2020

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 44 publications
(21 citation statements)
references
References 28 publications
0
21
0
Order By: Relevance
“…Compared with the presented asulam determination method, the methods in Table 5 show some disadvantages in the limit of detection, 1,4,5,7,8,12,37 linear dynamic range [3][4][5]10 , and the range of the sample analyzed. [1][2][3][4][5][6][7][8][9][10]12,37 Moreover, the analytical characteristics of the presented sulfide determination method were compared with the others as shown in Table 6. Compared with the presented sulfide enrichment/determination method, the others show some limitations in the limit of detection, 19,20,38−44 linear dynamic range, 20,42 and the range of the sample analyzed.…”
Section: Comparison With the Other Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Compared with the presented asulam determination method, the methods in Table 5 show some disadvantages in the limit of detection, 1,4,5,7,8,12,37 linear dynamic range [3][4][5]10 , and the range of the sample analyzed. [1][2][3][4][5][6][7][8][9][10]12,37 Moreover, the analytical characteristics of the presented sulfide determination method were compared with the others as shown in Table 6. Compared with the presented sulfide enrichment/determination method, the others show some limitations in the limit of detection, 19,20,38−44 linear dynamic range, 20,42 and the range of the sample analyzed.…”
Section: Comparison With the Other Methodsmentioning
confidence: 99%
“…This justifies asulam control in the environment in an accurate, sensitive, and selective manner. 1 Various analytical methods have been introduced for asulam determination in different samples. Some of the methods are chemiluminometric methods based on enhancing or inhibiting effects of asulam on the luminol/peroxidase system 2,3 and UV photoreaction-oxidation system, 1 electrocatalytic detection using nickel (II) phthalocyanine-multiwall carbon nanotubes (MWCNTs) 4 and cobalt(II) phthalocyanine modified MWCNTs, 5 an immunoassay method using a specific reactive antibody, 6 micellar electrokinetic capillary chromatography by UV and electrochemical detection, 7 capillary electrophoresis by UV and electrochemical detection, 8 ultra-HPLC-tandem MS 9 and spectrofluorimetry after derivatization with fluorescamine.…”
Section: Introductionmentioning
confidence: 99%
“…This solution was stable for at least for one week. 24 The working standard solutions were prepared daily by diluting the stock solution and protected against light.…”
Section: Solution Preparationmentioning
confidence: 99%
“…The UV irradiation proved to be an easy and clean way of derivatization to obtain fluorometric [27][28][29] or chemiluminescent structures. [30][31][32] A discussion of possible photoproducts is included. In order to automate the method, a flow injection analysis (FIA) manifold was developed.…”
Section: Introductionmentioning
confidence: 99%