2020
DOI: 10.1186/s12903-020-01129-z
|View full text |Cite
|
Sign up to set email alerts
|

New experimental setup for the measurement of cleaning efficacy and force of interdental aids in 3D-reproduced interdental areas

Abstract: Background: Interdental rubber picks (IRP) have become a frequent and convenient alternative for interdental cleaning. However, only little evidence exists supporting the effectiveness of newer designs available on the market. Therefore, a new in vitro model was evaluated to measure the experimental cleaning efficacy (ECE), as well as the force needed for insertion and during the use of IRP, with high reproducibility. Methods: Five different sizes of commercially marketed IRP with elastomeric fingers (IRP-F) (… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
18
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(21 citation statements)
references
References 20 publications
3
18
0
Order By: Relevance
“…1 . As explained in detail in our previous publication [ 10 ], we used a computer software (Autodesk Fusion 360, Autodesk Direct Limited, Hampshire, United Kingdom) and in vivo data of interdental morphologies [ 12 – 14 ] to design and print 3D composite replicas in stereolithography manner (Form 2, Formlabs Sommerville, MA, USA) by using liquid photopolymer resin (White Resin V04 (RS-F2-GPWH-04), Formlabs, Sommerville, MA, USA). This experimental setup was originally developed, in order to achieve the highest possible reproducibility and accuracy [ 15 ].…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…1 . As explained in detail in our previous publication [ 10 ], we used a computer software (Autodesk Fusion 360, Autodesk Direct Limited, Hampshire, United Kingdom) and in vivo data of interdental morphologies [ 12 – 14 ] to design and print 3D composite replicas in stereolithography manner (Form 2, Formlabs Sommerville, MA, USA) by using liquid photopolymer resin (White Resin V04 (RS-F2-GPWH-04), Formlabs, Sommerville, MA, USA). This experimental setup was originally developed, in order to achieve the highest possible reproducibility and accuracy [ 15 ].…”
Section: Methodsmentioning
confidence: 99%
“…Subsequently, the interdental area replicas were stained by one investigator (K.S.) with Occlu Spray Plus (Hager & Werke, Duisburg, Germany) as described in previous studies [ 10 , 16 , 17 ]. A standardized powder thickness (mean ± SD: 20 ± 5 µm) was ensured by a standardized procedure and appropriate time protocol.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations