2001
DOI: 10.1016/s0022-0728(01)00358-8
|View full text |Cite
|
Sign up to set email alerts
|

New electrochemical sensors for detection of nitrites and nitrates

Abstract: Platinum electrodes modified with a cellulose acetate membrane or with poly(1,8-diaminonaphthalene) film were assembled and used for rapid amperometric detection of nitrites and nitrates in water by batch and flow injection analysis.Parameters such as the permeability of the electropolymerised films to nitrites and nitrates, interference effects and recovery studies of these kinds of sensors have been optimised to demonstrate the analytical suitability of the proposed method.Contrary to the standard colorimetr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
79
0

Year Published

2003
2003
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 143 publications
(86 citation statements)
references
References 22 publications
1
79
0
Order By: Relevance
“…There are numerous methods developed so far for the determination of nitrite in environmental samples, which include spectrofluorometry [10][11][12], chromatography [13][14][15][16], potentiometry [17][18][19], capillary electrophoresis [20][21][22], membrance sensors [23,24], flow injection analysis [25][26][27][28][29], electroanalytical [30,31], and amperometric [32,33]. Most of these methods are not suitable for routine determination of nitrite in environmental samples because some of them are costly or need skilled person to handle.…”
Section: Introductionmentioning
confidence: 99%
“…There are numerous methods developed so far for the determination of nitrite in environmental samples, which include spectrofluorometry [10][11][12], chromatography [13][14][15][16], potentiometry [17][18][19], capillary electrophoresis [20][21][22], membrance sensors [23,24], flow injection analysis [25][26][27][28][29], electroanalytical [30,31], and amperometric [32,33]. Most of these methods are not suitable for routine determination of nitrite in environmental samples because some of them are costly or need skilled person to handle.…”
Section: Introductionmentioning
confidence: 99%
“…After rinsing with distilled water, the electrodes were pre-treated by potential cycling in 0.5 M H 2 SO 4 from −0.2 to +1.2 versus Ag|AgCl at a scan rate of 20 mV/s, until no changes were observed in the cyclic voltammograms [12].…”
Section: Electrode Polishingmentioning
confidence: 99%
“…Film permeability was evaluated measuring the peak current by cyclic voltammetry for each analyte. Then the permeability (P%) was calculated using the equation (1), as described in [12]:…”
Section: Study Of Permeabilitymentioning
confidence: 99%
See 1 more Smart Citation
“…Polarography is often employed 1,3,28,29 and this and other electrochemical methods are used in conjunction with other regimes such as high performance liquid chromatography. 4,[6][7][8][30][31][32] Electrochemical detection is mostly performed at copper modified electrodes [33][34][35][36][37][38][39][40][41][42][43][44][45][46] although other electrodes such as Pt modified with cellulose acetate membrane, 47 gold plated porous membrane, 48 yeast modified glassy carbon 49 and yeast modified screen printed carbon 49 have been investigated. Ion selective electrodes can be used to avoid the effects of common interferences.…”
mentioning
confidence: 99%