Proceedings ICT'03. 22nd International Conference on Thermoelectrics (IEEE Cat. No.03TH8726)
DOI: 10.1109/ict.2003.1287560
|View full text |Cite
|
Sign up to set email alerts
|

New approach for highly accurate efficiency determination of thermoelectric generator modules

Abstract: An experimental method was developed to determine the efficiency of thermoelectric generators with enhanced reliability and accuracy. In spite of previous experiments the crucial

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 1 publication
0
3
0
Order By: Relevance
“…A few home‐built systems to evaluate the performance of high temperature modules have been developed at various laboratories. For example, Rauscher et al developed a novel approach to measure TE modules with their set‐up . An alternative approach which overcomes problems regarding calibration, temperature measurement and heat loss is to determine the heat production instead of measuring the electrical power.…”
Section: Design Principle Fabrication Methods and Testing Technologmentioning
confidence: 99%
“…A few home‐built systems to evaluate the performance of high temperature modules have been developed at various laboratories. For example, Rauscher et al developed a novel approach to measure TE modules with their set‐up . An alternative approach which overcomes problems regarding calibration, temperature measurement and heat loss is to determine the heat production instead of measuring the electrical power.…”
Section: Design Principle Fabrication Methods and Testing Technologmentioning
confidence: 99%
“…GHPs for heat flow measurement on TEMs involving actively controlled guard heaters for thermal shielding of the MH have been described by Anatychuk et al [ 96 ], Kwon et al [ 97 ], Rauscher et al [ 98 , 99 ], and Ziolkowski et al [ 51 ]. Anatychuk developed a GHP and tested the accuracy of the MH against a custom-made heat flux sensor, which was installed at the cold side of a tested TEM.…”
Section: Methodsmentioning
confidence: 99%
“…The issue with this method is that the thermal conductivity of the reference block needs to be calibrated in advance, and the heat loss from the reference block and heat source is difficult to estimate and correct. The guard heater arrangement proposed by Rauscher et al [22,23] was adopted in this work to overcome these issues. The primary heater block was used to supply heating power.…”
Section: Test Setupmentioning
confidence: 99%