2021
DOI: 10.3389/fphys.2021.634779
|View full text |Cite
|
Sign up to set email alerts
|

New Advances in Monitoring Cardiac Output in Circulatory Mechanical Assistance Devices. A Validation Study in a Porcine Model

Abstract: Cardiac output (CO) measurement by continuous pulmonary artery thermodilution (COCTD) has been studied in patients with pulsatile-flow LVADs (left ventricular assist devices), confirming the clinical utility. However, it has not been validated in patients with continuous-flow LVADs. Therefore, the aim of this study was to assess the validity of COCTD in continuous-flow LVADs. Continuous-flow LVADs were implanted in six miniature pigs for partial assistance of the left ventricle. Both methods of measuring CO—me… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(7 citation statements)
references
References 44 publications
(59 reference statements)
0
7
0
Order By: Relevance
“…PAC is still recommended by the interdisciplinary S3 guidelines in a cardiac surgical setting, and this indication includes patients with LVADs (Kanchi, 2011;Habicher et al, 2018). Continuous thermodilution by PAC has been validated in both continuous-flow (Quintana-Villamandos et al, 2021) and pulsatile-flow (Mets et al, 2002) LVADs, because it is crucial to know the status of end-organ perfusion in these patients (Birati and Rame, 2014). In a previous study, our group has Frontiers in Physiology frontiersin.org validated continuous thermodilution by PAC using intermittent thermodilution by PAC (standard technique), in six minipigs with continuous-flow LVADs (Quintana-Villamandos et al, 2021).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…PAC is still recommended by the interdisciplinary S3 guidelines in a cardiac surgical setting, and this indication includes patients with LVADs (Kanchi, 2011;Habicher et al, 2018). Continuous thermodilution by PAC has been validated in both continuous-flow (Quintana-Villamandos et al, 2021) and pulsatile-flow (Mets et al, 2002) LVADs, because it is crucial to know the status of end-organ perfusion in these patients (Birati and Rame, 2014). In a previous study, our group has Frontiers in Physiology frontiersin.org validated continuous thermodilution by PAC using intermittent thermodilution by PAC (standard technique), in six minipigs with continuous-flow LVADs (Quintana-Villamandos et al, 2021).…”
Section: Discussionmentioning
confidence: 99%
“…We use six healthy mini-pigs with a mean weight of 42.8 ± 9.9 kg. The previously described anesthetic protocol was applied (Morillas-Sendín et al, 2015;Quintana-Villamandos et al, 2021). After premedication with 20 mg/kg intramuscular ketamine (Ketolar, Parke-Davis, Madrid, Spain) and 0.04 mg/kg atropine (Atropina Braun, Serra Pamies, Reus, Spain), anesthesia was induced with 2.5 μg/kg intravenous fentanyl (Fentanest, Kern Pharma, Barcelona, Spain) and 4 mg/kg propofol (Diprivan 1%, AstraZeneca, Madrid, Spain).…”
Section: Anaesthesia and Surgical Protocolmentioning
confidence: 99%
See 1 more Smart Citation
“…24 A new generation of PACs can allow for continuous CO measurement. 25 This new technology utilizes heat instead of cold thermodilution via a thermal filament connected to a specialized PAC and a distal thermistor. 25 However, this new generation PACs is still not available at our unit.…”
Section: Discussionmentioning
confidence: 99%
“…25 This new technology utilizes heat instead of cold thermodilution via a thermal filament connected to a specialized PAC and a distal thermistor. 25 However, this new generation PACs is still not available at our unit. Several less invasive commercial devices for continuous cardiac output based on arterial waveform are currently available PiCCO (pulse contour cardiac output), LiDCO (lithium dilution cardiac output) and flowtrac/vigileo system).…”
Section: Discussionmentioning
confidence: 99%