2012
DOI: 10.1016/j.fusengdes.2012.02.129
|View full text |Cite
|
Sign up to set email alerts
|

Neutronics diagnostics for European ITER TBMs: Activation foil spectrometer for short measurement cycles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 5 publications
(5 reference statements)
0
4
0
Order By: Relevance
“…A set of suitable dosimetry reactions were proposed for use in a TBM foil-based spectrometry system [5], a subset of which can be seen in Table 1, using criteria such as intensity and number of emitted gamma lines and half-life. The proposed short half-life reactions cover a range of energy threshold and non-threshold reactions and require a limited number of different high-purity foils that will be compatible with the environmental conditions expected of the ITER TBMs.…”
Section: An Activation Foil-based Spectrometer Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…A set of suitable dosimetry reactions were proposed for use in a TBM foil-based spectrometry system [5], a subset of which can be seen in Table 1, using criteria such as intensity and number of emitted gamma lines and half-life. The proposed short half-life reactions cover a range of energy threshold and non-threshold reactions and require a limited number of different high-purity foils that will be compatible with the environmental conditions expected of the ITER TBMs.…”
Section: An Activation Foil-based Spectrometer Systemmentioning
confidence: 99%
“…Thinner foils are proposed for testing in future D-T operations, but for testing and validation of associated processes in D-D conditions, and bearing in mind the detection limits, these thicker foils were needed. Although Ce foils were proposed in [5], investigations regarding the suitability of the material for irradiation under the JET D-D environment deemed the material unsuitable in its elemental form.…”
Section: Selection Of Dosimetry Foilsmentioning
confidence: 99%
“…However knowledge of the first wall spectrum is essential for monitoring the power output of the fusion reactor [5], predicting its tritium breeding ratio [6], inferring the radiation damage to the structural components, validating the radiation transport models for shielding components [7], as well as supplementing the plasma parameter measurements [8]. Many of these activities are critical to the safety, sustainability, and viability of fusion as a commercial energy source.…”
Section: Introductionmentioning
confidence: 99%
“…However, the technique of neutron-spectrum unfolding using activation foils requires optimisation for measuring fusion neutron spectra. Previous investigations have only selected foils on an ad hoc basis (see [5,6,9] for example). In this paper, a programmatic approach to foil selection is shown to increase the precision provided by neutron activation systems.…”
Section: Introductionmentioning
confidence: 99%