1986
DOI: 10.1063/1.1138559
|View full text |Cite
|
Sign up to set email alerts
|

Neutron spectrometry at JET (invited)

Abstract: A diamond based neutron spectrometer for diagnostics of deuterium-tritium fusion plasmas Review of Scientific Instruments 85, 11E101 (2014);

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
21
0

Year Published

1987
1987
2019
2019

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(23 citation statements)
references
References 7 publications
1
21
0
Order By: Relevance
“…There is a quite broad range of techniques and detectors that can (and have been) used for fusion neutron spectroscopy [26,27]: they span from small compact single detectors/monitors of a few kg to very specialized instrument systems of considerable weight (10's of tons) and size (several m 3 ). Some of the more common techniques are schematically depicted in Fig.…”
Section: Review Of Neutron Spectrometry Techniques: Compact Detectorsmentioning
confidence: 99%
See 1 more Smart Citation
“…There is a quite broad range of techniques and detectors that can (and have been) used for fusion neutron spectroscopy [26,27]: they span from small compact single detectors/monitors of a few kg to very specialized instrument systems of considerable weight (10's of tons) and size (several m 3 ). Some of the more common techniques are schematically depicted in Fig.…”
Section: Review Of Neutron Spectrometry Techniques: Compact Detectorsmentioning
confidence: 99%
“…8, many of the neutron detection techniques listed in ''The Fusion Plasma as a Neutron Source: The Direct Emission'' section have been tested and used in fusion. JET in particular has over the years had an ambitious program of neutron diagnostics, including, in particular, several different types of neutron spectrometers [26].…”
Section: Review Of Neutron Spectrometry Techniques: Compact Detectorsmentioning
confidence: 99%
“…Higher energy resolution is gained at the expense of detection efficiency. Many neutron detector types have been used for neutron spectrometry of tokamak plasmas [43,44,45,46,47,48,49,50]. There have been also several attempts to use solid state detectors, like Silicon diodes or more recently diamond detectors, to measure neutron spectra, with a resolution in the range of 0.8% and an efficiency of about 10 −4 cm 2 .…”
Section: Pos(fnda2006)091mentioning
confidence: 99%
“…N eu tro n diagnostics are also used to m easure ion tem peratures in d eu teriu m plasm as (Jarvis et al 1987). T h e n eu tro n yield from a d euterium plasm a w ith a M axw ellian-ion distribution is p ro portional to the square of the d euteron density and to a high pow er of the ion tem perature.…”
Section: Plasma Measurements For Jet 53 E Lectron Densitymentioning
confidence: 99%