2012
DOI: 10.1063/1.4728095
|View full text |Cite
|
Sign up to set email alerts
|

Neutron spectrometry—An essential tool for diagnosing implosions at the National Ignition Facility (invited)

Abstract: DT neutron yield (Y(n)), ion temperature (T(i)), and down-scatter ratio (dsr) determined from measured neutron spectra are essential metrics for diagnosing the performance of inertial confinement fusion (ICF) implosions at the National Ignition Facility (NIF). A suite of neutron-time-of-flight (nTOF) spectrometers and a magnetic recoil spectrometer (MRS) have been implemented in different locations around the NIF target chamber, providing good implosion coverage and the complementarity required for reliable me… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
34
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
9
1

Relationship

4
6

Authors

Journals

citations
Cited by 124 publications
(34 citation statements)
references
References 23 publications
0
34
0
Order By: Relevance
“…For the 14.1 MeV, we obtained a total cross section, σ nCD2 = σ nC +2σ nD = 1.5 b+ 2×0.85 b =3.2 b. From the quaternary collisions we can also obtain an estimate of the areal density using the Down Scatter Ratio (DSR), the ratio of the number of neutrons with energy between 10 and 12 MeV (N 4 ) divided by the total number of ternary fusion reactions (N 3 -14.1 MeV neutrons): ρΛ=(20.4±0.6)DSR [23,21,51,48].…”
mentioning
confidence: 99%
“…For the 14.1 MeV, we obtained a total cross section, σ nCD2 = σ nC +2σ nD = 1.5 b+ 2×0.85 b =3.2 b. From the quaternary collisions we can also obtain an estimate of the areal density using the Down Scatter Ratio (DSR), the ratio of the number of neutrons with energy between 10 and 12 MeV (N 4 ) divided by the total number of ternary fusion reactions (N 3 -14.1 MeV neutrons): ρΛ=(20.4±0.6)DSR [23,21,51,48].…”
mentioning
confidence: 99%
“…The MRS yield has been compared to the NADs measurements, averaged over several different lines-of-sight, 21 which are also absolutely calibrated (the NIF nTOF detectors were calibrated with the MRS and NADs data and thus excluded in this comparison). 23 The yields determined from the MRS data, as a function of the activation data, are shown in Figure 3. Here, five different CD 2 foils were used with thickness ranging from 47 to 259 μm.…”
Section: Mrs Measurements Of the Yield On Omega And The Nifmentioning
confidence: 99%
“…The Specs all employ the same JAC Black detector assembly, a four channel detector opposite a centralized scintillator 17 , which has been optimized for measurement of the downscatter fraction. The design driver for this assembly was to reduce mass to a minimum within a radial boundary from the scintillator such that neutron re-scatter would not corrupt the downscatter ratio measurement.…”
Section: Ntof Spec Diagnosticsmentioning
confidence: 99%