2017
DOI: 10.3390/qubs1010006
|View full text |Cite
|
Sign up to set email alerts
|

Neutron Sources at the Frank Laboratory of Neutron Physics of the Joint Institute for Nuclear Research

Abstract: The IBR-2 reactor and IREN facility are the two main neutron sources at the Frank Laboratory of Neutron Physics. This contribution presents data on the IBR-2 reactor parameters before and after modernization. The general schemes of the IBR-2 reactor as well as of the IREN facility are presented.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(11 citation statements)
references
References 19 publications
0
7
0
1
Order By: Relevance
“…Experiments on small-angle scattering of neutrons using time-of-flight spectrometer YuMO [7], [8] were carried out on pulse reactor IBR-2 in JINR (Dubna) [9], at the distance sample -detector 5.28 and 13.04 m, providing the range of obtained values of scattering vector Q from 0.007 to 0.5 Ǻ -1 . Diameter of irradiated area of the sample was 14 mm.…”
Section: Materials and Experimental Methodsmentioning
confidence: 99%
“…Experiments on small-angle scattering of neutrons using time-of-flight spectrometer YuMO [7], [8] were carried out on pulse reactor IBR-2 in JINR (Dubna) [9], at the distance sample -detector 5.28 and 13.04 m, providing the range of obtained values of scattering vector Q from 0.007 to 0.5 Ǻ -1 . Diameter of irradiated area of the sample was 14 mm.…”
Section: Materials and Experimental Methodsmentioning
confidence: 99%
“…функциональном рентгеновском дифрактометре Rigaku Ultima IV с использованием программного комплекса PDXL (X-ray Powder Diffraction Software) с базой порошковых дифракционных стандартов PDF-2. Для исследований при помощи нейтронов использованы установки на импульсном реакторе ИБР-2 в ОИЯИ [9]. Для выявления мелкодисперсных карбидных составляющих стали был использован нейтронный текстурный дифрактометр СКАТ.…”
Section: материалы и методы исследованияunclassified
“…The Frank Laboratory of Neuron Physics at JINR (Dubna, Russia), the basic facility of which is the IBR-2 high-flux pulsed reactor [20], has more than twenty years of experience in the development of neutron scattering methods at high pressure [17,[21][22][23]. The high-pressure cells with sapphire anvils opposite are used on a specialized neutron diffractometer DN-12 for micro-sample studies [21].…”
Section: Introductionmentioning
confidence: 99%