2006
DOI: 10.1063/1.2354902
|View full text |Cite
|
Sign up to set email alerts
|

Neutron Scattering Studies On Stoner Gap In The Superconducting Ferromagnet UGe2 By Using A Small Piston-Cylinder-Type Clamp Cell

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2006
2006
2021
2021

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…1). In such a case, the experimetal results could be obscured by even a small pressure distribution within the sample [10,18].) Since it is unclear which is dominant, we tentatively tried to apply the Stoner model to the FM2 region.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…1). In such a case, the experimetal results could be obscured by even a small pressure distribution within the sample [10,18].) Since it is unclear which is dominant, we tentatively tried to apply the Stoner model to the FM2 region.…”
Section: Resultsmentioning
confidence: 99%
“…The pressure was generated using a copperberyllium (CuBe) based piston-cylinder clamp device [10] with Fluorinert FC-75 (3M Co. Ltd., Tokyo) as a pressure transmitting medium. The low temperature pressure was determined by measurements of the change in a lattice parameter of NaCl put together with the sample.…”
Section: Methodsmentioning
confidence: 99%
“…For measurements with p < 2 GPa (experiment N1), a pistoncylinder cell was used, which is similar in design to the one in Ref. [44]. For measurements with p > 2 GPa (experiment N2), a clamp-type palm cubic anvil cell (PCAC) was used with ZrO 2 anvils and a gasket made out of an Al-based alloy [45].…”
Section: Experimental Methodsmentioning
confidence: 99%
“…For measurements with p < 2 GPa, a piston-cylinder cell was used, which is similar in design to the one in Ref. [44]. We refer to these experiments throughout the text as N1.…”
Section: F Neutron-diffraction Measurements At Hb1 On Single Crystalmentioning
confidence: 99%
“…Thus, there exists a strong need to develop a smaller and more convenient pressure cell for LT ND measurements. Recently, we reported the design and basic properties of a small CuBe-based clamp cell for LT ND measurements, 4) and it was successfully used for studies of a pressure-induced superconducting ferromagnet UGe 2 , 5) a valence transition compound YbMn 2 Ge 2…”
mentioning
confidence: 99%