Neutralisation and transport of negative ion beams: physics and diagnostics

Abstract: Neutral beam injection is one of the most important methods of plasma heating in thermonuclear fusion experiments, allowing the attainment of fusion conditions as well as driving the plasma current. Neutral beams are generally produced by electrostatically accelerating ions, which are neutralised before injection into the magnetised plasma. At the particle energy required for the most advanced thermonuclear devices and particularly for ITER, neutralisation of positive ions is very inefficient so that negative … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0
3

Year Published

2017
2017
2020
2020

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 38 publications
(20 citation statements)
references
References 130 publications
(164 reference statements)
0
17
0
3
Order By: Relevance
“…An optimum energetic efficiency is mandatory and the very large scale of the device and handling of 1280 beamlets sets a serious challenge. Serianni et al present the status of the space charge compensation, charge exchange and beam dynamics simulation and describe the outlook of its experimental validation [32].…”
Section: Negative Ion Source Beam Intensities Across 20 Orders Of Magmentioning
confidence: 99%
“…An optimum energetic efficiency is mandatory and the very large scale of the device and handling of 1280 beamlets sets a serious challenge. Serianni et al present the status of the space charge compensation, charge exchange and beam dynamics simulation and describe the outlook of its experimental validation [32].…”
Section: Negative Ion Source Beam Intensities Across 20 Orders Of Magmentioning
confidence: 99%
“…В реальности идеальную настройку бимлет относительно оси инжекции -как по горизонтали, так и по вертикали -осуществить сложно [6], всегда есть отклонения, неточности фокусировки, которые обусловлены ограниченной точностью изготовления и монтажа электродов, а также их термическими деформациями. Кроме того, имеются физически обусловленные факторы -действие объёмного заряда соседних бимлет на стадии их ускорения в ИОС и влияние магнитных полей, перехватывающих электроны в области вытягивания и ускорения ионов в источнике.…”
Section: инжекторunclassified
“…D 2 or H 2 is injected midway along each neutraliser channel. The neutralization efficiency of the high energy negative ion beam is expected to be about 60%, so a significant amount of positive and negative ions have to be filtered downstream of the neutralizer [65].…”
Section: The Mitica Beam Line Components and Diagnosticsmentioning
confidence: 99%