2002
DOI: 10.1016/s0378-7753(01)01051-5
|View full text |Cite
|
Sign up to set email alerts
|

Networked solid oxide fuel cell stacks combined with a gas turbine cycle

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2004
2004
2018
2018

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 57 publications
(17 citation statements)
references
References 3 publications
0
17
0
Order By: Relevance
“…If the isolation or a high ratio of the voltage conversion is required, a transformer is usually integrated into the system. The main drawback for this configuration is that the low-frequency transformer placed at the output of the inverter makes the system very bulky and expensive (Palsson et al, 2000;Costamagna et al, 2001;Bayoumi et al, 2001Bayoumi et al, , 2002Selimovic and Palsson, 2002;Alcaide et al, 2006;Pillai et al, 2008;Maamoun et al, 2002). 2 It produces sufficient voltage for the inverter input so that the required magnitude of the AC voltage can be produced .…”
Section: Fuel Cell System Configurationsmentioning
confidence: 99%
See 2 more Smart Citations
“…If the isolation or a high ratio of the voltage conversion is required, a transformer is usually integrated into the system. The main drawback for this configuration is that the low-frequency transformer placed at the output of the inverter makes the system very bulky and expensive (Palsson et al, 2000;Costamagna et al, 2001;Bayoumi et al, 2001Bayoumi et al, , 2002Selimovic and Palsson, 2002;Alcaide et al, 2006;Pillai et al, 2008;Maamoun et al, 2002). 2 It produces sufficient voltage for the inverter input so that the required magnitude of the AC voltage can be produced .…”
Section: Fuel Cell System Configurationsmentioning
confidence: 99%
“…Therefore, the output voltage should be regulated at a desired value. To keep the polarisation characteristic at a constant level, additional parameters such as cell temperature, air pressure, oxygen partial pressure, and membrane humidity also need to be controlled (Selimovic and Palsson, 2002).…”
Section: Generalised Pes Circuit and Controlmentioning
confidence: 99%
See 1 more Smart Citation
“…recuperator, steam boiler, and heat exchanger network). Selimovic et al, 2002 proposed that networked SOFC stacks incorporated with gas turbine be used to further produce electricity from an exhaust gas combustion stream. It is known that a gas turbine is classified as a low efficiency mechanical power device as well as an entropy lost afterburner.…”
Section: Heat Recovery Sectionmentioning
confidence: 99%
“…In another approach, Burer et al [4] presents a SOFC/gas-turbine hybrid as one subset of a larger power, heating, and cooling cogeneration system model. Palsson, et al [5] developed a two-dimensional planar SOFC model to add further fidelity and flexibility to the system and proceeded to evaluate several novel concepts, including networked SOFC stacks [6]. Even ground-based mobile applications using hybrid SOFC/gas turbines have been examined, presented by Winkler and Lorenz [7].…”
Section: Introductionmentioning
confidence: 99%