2012
DOI: 10.1109/tste.2012.2191581
|View full text |Cite
|
Sign up to set email alerts
|

Negative Sequence Current Control in Wind Power Plants With VSC-HVDC Connection

Abstract: Large offshore wind power plants may have multi-MW wind turbine generators (WTG) equipped with full-scale converters (FSC) and voltage source converter (VSC) based high voltaage direct-current (HVDC) transmission for grid connection. The power electronic converters in the WTG-FSC and the VSC-HVDC allow fast current control in the offshore grid. This paper presents a method of controlling the negative sequence current injection into the offshore grid from the VSC-HVDC as well as WTG-FSCs. This would minimize th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
44
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 106 publications
(55 citation statements)
references
References 16 publications
0
44
0
Order By: Relevance
“…Additionally, the VSC is also expected to deal with harmonic distortion, following network recommendations and standards [13][14][15][16][17][18][19][20].…”
Section: -Control Methods Under Adverse Ac Conditionsmentioning
confidence: 99%
See 2 more Smart Citations
“…Additionally, the VSC is also expected to deal with harmonic distortion, following network recommendations and standards [13][14][15][16][17][18][19][20].…”
Section: -Control Methods Under Adverse Ac Conditionsmentioning
confidence: 99%
“…Therefore, several solutions have been explored in the past, by appropriately injecting synthesized currents to attenuate power oscillations. These control strategies include rotating reference frames [86,87] with proportional-integral controllers [85,88], stationary frames [17] with proportional-resonant controllers [16,89], as well as nonlinear hysteresis and predictive deadbeat controllers, among others [90].…”
Section: -Control Methods Under Adverse Ac Conditionsmentioning
confidence: 99%
See 1 more Smart Citation
“…• Advantages : Black start capability [19], no requirement for reactive power compensation, more compact and lighter compared to LCC, no need for harmonic filter, can be operated in both capacitive or inductive modes [20], [21], VSC valves are independent of the zero crossings of the current and balanced operation of the linked AC system, ability to control the negative sequence current injection in the offshore wind power plant [22], shorter design and installation times [15], using IGBT switches enables the VSC-HVDC scheme to be switched on and off at higher rate [23] and needs no external voltage source for commutation [24].…”
Section: ) Utilized Hvdc Technologymentioning
confidence: 99%
“…seq. handling by WT converters is treated in [10,11,12,13,14,15,16,17,18] and in the light of VSC-HVDC-interfaced AC grids in [19,20,21,22]. Converter control regarding neg.…”
Section: Introductionmentioning
confidence: 99%