Abstract: Needle insertion is common during minimally invasive interventions such as biopsy or brachytherapy. During soft tissue needle insertion, forces acting at the needle tip cause tissue deformation and needle deflection. Accurate needle tip force measurement provides information on needle-tissue interaction and helps detecting and compensating potential misplacement. For this purpose we introduce an image-based needle tip force estimation method using an optical fiber imaging the deformation of an epoxy layer belo… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
9
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 16 publications
1
9
0
Order By: Relevance
“…In addition, we provide qualitative results for tissue insertion experiments, showing the feasibility of the approach. This work extends preliminary results we presented at MICCAI 2018 [27]. We substantially revised and extended the original paper with an extended review of the relevant literature, a more detailed explanation of our novel convGRU-CNN model and additional experiments for the model.…”
Section: Introductionsupporting
confidence: 61%
See 1 more Smart Citation
“…In addition, we provide qualitative results for tissue insertion experiments, showing the feasibility of the approach. This work extends preliminary results we presented at MICCAI 2018 [27]. We substantially revised and extended the original paper with an extended review of the relevant literature, a more detailed explanation of our novel convGRU-CNN model and additional experiments for the model.…”
Section: Introductionsupporting
confidence: 61%
“…Furthermore, we employ recurrent dropout for additional regularization [29] at the cell input with probability p di = 0.1 and at the cell output with probability p do = 0.2. Recurrent batch normalization and dropout are extensions to the original model presented in [27] and the new model is named convGRU-CNN+. We add these augmentations to all recurrent models.…”
Section: Deep Learning Architecturesmentioning
confidence: 99%
“…However, biased force measurement due to friction forces at the tool shaft is undesirable. Gessert et al [3] proposed a miniature force sensor integrated in the tool tip. These force sensors can be problematic due to sterilization, biocompatibility and integration in microsurgical instruments with a working channel.…”
Section: Problemmentioning
confidence: 99%
“…The diameter of the needle is 2 mm. In [2], the needle tip was constructed as a cone and attached to the needle shaft with a deformable epoxy layer. Thus, radial forces on the needle tip could easily tilt it.…”
Section: Needle Designmentioning
confidence: 99%
“…Here, we consider a setting where optical coherence tomography is B M. Gromniak martin.gromniak@tuhh.de 1 Institute of Medical Technology, Hamburg University of Technology, Hamburg, Germany available, e.g., to study tissue deformation [10] or to realize elastography [7]. While OCT has been proposed for tip forces estimation before [2,3], these approaches rely on the reconstructed gray value data. However, using the reconstructed data has two limitations.…”
Section: Introductionmentioning