1991
DOI: 10.1109/28.108471
|View full text |Cite
|
Sign up to set email alerts
|

Need for industry standards for AC induction motors intended for use with adjustable-frequency controllers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

1994
1994
2020
2020

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 48 publications
(9 citation statements)
references
References 0 publications
0
9
0
Order By: Relevance
“…(3). If γ is noticed as γ 2 = Z S Y S , then the solution of (3) is deducted as given by (4). V + (s) and V − (s) are Laplace transforms of the incident voltage wave V + (t) and the reflected one V − (t), respectively.…”
Section: Frequency Domain Analysis Of Traveling Voltage Waves and Itsmentioning
confidence: 99%
See 1 more Smart Citation
“…(3). If γ is noticed as γ 2 = Z S Y S , then the solution of (3) is deducted as given by (4). V + (s) and V − (s) are Laplace transforms of the incident voltage wave V + (t) and the reflected one V − (t), respectively.…”
Section: Frequency Domain Analysis Of Traveling Voltage Waves and Itsmentioning
confidence: 99%
“…Qualitative analysis relating to this phenomenon has been reported in the literature [7,8] as well as the impact of the phenomenon on the motor and/or the cable [4,6,10,19]. Some mitigation techniques, especially to design output filters capable of matching the cable's characteristic impedance [1,13], have also been proposed.…”
Section: Introductionmentioning
confidence: 96%
“…Having Buck type converter design and too high DC operating voltage is one of the reasons for large difference in water output in summer and winter season even though the radiation on module plane is same. Lots of people have done research on the MPPT algorithms, based on constant voltage, perturb and observe, and incremental conductance methods (Moulay-Idriss and Mohamed, 2013; Kassem, 2012;Mohammedi et al, 2014) and effect of power quality on motor insulation (Persson, 1992;Bonnett, 1996;Melhorn and Tang, 1995;Hyypio, 1997;Daugherty and Wennerstrom, 1990;Mecker, 1992). Industry grade VFDs are traditionally used for solar water pumping systems to drive induction motors, however limitations in the performance of VFD encouraged researcher to design a new pump controller such as Sine-wave Pump Controller with MPPT (SPCM).…”
Section: Introductionmentioning
confidence: 98%
“…Qualitative analysis relating to this phenomenon has been reported in the literature [1][2][3]. Several authors have studied the impact of the phenomenon on the motor and/or the cable [4,[5][6][7][8][9]. Others proposed some mitigation techniques, especially to design output filters capable of matching the cable's characteristic impedance [10,11].…”
Section: Introductionmentioning
confidence: 99%