2023
DOI: 10.1039/d2ja00319h
|View full text |Cite
|
Sign up to set email alerts
|

Nebulization assisted molecular LIBS for sensitive and fast fluorine determination in aqueous solutions

Abstract: The determination of halogen content in liquid samples by conventional Laser Induced Breakdown Spectroscopy (LIBS) is a difficult task due to the high excitation threshold of these elements. The indirect...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 19 publications
0
4
0
Order By: Relevance
“…Instrumentation. A novel calibration approach based on online nebulisation of different concentrations of an aqueous solution of NaF onto a CaCO 3 pellet was developed and optimised by Méndez-López et al 104 to obtain F concentration calibration curves from LIBS molecular emission of CaF. The method provided LODs for F of 10 mg kg −1 with a linear response range up to 900 mg kg −1 .…”
Section: Laser Induced Breakdown Spectroscopymentioning
confidence: 99%
“…Instrumentation. A novel calibration approach based on online nebulisation of different concentrations of an aqueous solution of NaF onto a CaCO 3 pellet was developed and optimised by Méndez-López et al 104 to obtain F concentration calibration curves from LIBS molecular emission of CaF. The method provided LODs for F of 10 mg kg −1 with a linear response range up to 900 mg kg −1 .…”
Section: Laser Induced Breakdown Spectroscopymentioning
confidence: 99%
“…4.1.2 Instrumentation. A novel approach based on online nebulisation of different concentrations of an aqueous solution containing halogens (e.g., NaF), directed towards a substrate containing an alkali-earth metal (e.g., a CaCO 3 pellet), was developed by Méndez-López et al 137 to obtain proper F calibration curves from molecular emission (e.g., for CaF). The optimised microanalysis conguration resulted in an LOD of 10 mg kg −1 with a linear range up to 900 mg kg −1 .…”
Section: Laser Induced Breakdown Spectroscopy (Libs)mentioning
confidence: 99%
“…, NaF), directed towards a substrate containing an alkali-earth metal ( e.g. , a CaCO 3 pellet), was developed by Méndez-López et al 137 to obtain proper F calibration curves from molecular emission ( e.g. , for CaF).…”
Section: Laser-based Atomic Spectrometrymentioning
confidence: 99%
“…Mendez-Lopez et al nebulized an aqueous solution of NaF onto the Ca-containing pellets to obtain molecular emission bands of CaF. 46 This method was used to detect fluorine content in liquids, and the experimental accuracy deviation of the three mouthwashes measured was less than 10%. In addition to solids and liquids, the use of molecular emission bands is also feasible in aerosols.…”
Section: Case Studiesmentioning
confidence: 99%