1999
DOI: 10.1021/ac990517x
|View full text |Cite
|
Sign up to set email alerts
|

Near-Infrared Surface Plasmon Resonance Measurements of Ultrathin Films. 1. Angle Shift and SPR Imaging Experiments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
219
1

Year Published

2000
2000
2023
2023

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 272 publications
(222 citation statements)
references
References 33 publications
2
219
1
Order By: Relevance
“…Angular dependent intensities of SPCECL (bottom). The upper panel shows the reflectivity of the gold film calculated using a gold dielectric constant of ε m = −10.5 + 1.49i and the software from [23,24] and http://corninfo.chem.wisc.edu Emission spectra of [Ru(bpy) 3 ] 2+ (top) and of SPCECL in acetonitrile (bottom).…”
Section: Discussionmentioning
confidence: 99%
“…Angular dependent intensities of SPCECL (bottom). The upper panel shows the reflectivity of the gold film calculated using a gold dielectric constant of ε m = −10.5 + 1.49i and the software from [23,24] and http://corninfo.chem.wisc.edu Emission spectra of [Ru(bpy) 3 ] 2+ (top) and of SPCECL in acetonitrile (bottom).…”
Section: Discussionmentioning
confidence: 99%
“…Indeed, optical techniques of various types are emerging as an important tool for monitoring the dynamics of biomolecule interactions on a solid surface. For instance, imaging surface plasmon resonance spectroscopy (SPR), 23,24 imaging optical ellipsometry (OE), 25 and reflectometric interference spectroscopy (RIFS) 26 are 3 label-free optical techniques that in essence measure the same optical dielectric response of a thin film and thereby detect changes of physical or chemical properties of the thin film such as thickness and mass density during biochemical reactions. Compared with the above 3 methods, the OIRD technique is a more sensitive form of ellipsometry that measures the difference in reflectivity between the s-and p-polarized lights.…”
Section: Introductionmentioning
confidence: 99%
“…It is apparent from the curves that the largest change in signal (of the three) occurs at the mid-range resonance wavelength of 770 nm. One common measure of the signal change due to absorptive particles used in previous reports [6,17] is the maximum change in reflectivity; with this measure, the signal change due to colloidal gold nanoparticles is approximately 30% at 650 nm, 49% at 770 nm, and 47% at 920 nm. An alternative measure, which depends on the difference curve across the investigated wavelength range and more completely describes the quantifiable difference in such signals, is the sum of the absolute value of the difference curve [5].…”
Section: Resultsmentioning
confidence: 99%