Near-Infrared Spectroscopy: A Promising Prehospital Tool for Management of Traumatic Brain Injury

Abstract: Promising results were obtained using the InfraScan NIRS device in prehospital screening for intracranial hematomas in TBI patients. High sensitivity and good specificity were found. Further research is necessary to determine the beneficial effects of enhanced prehospital screening on triage, survival, and quality of life in TBI patients. Peters J , Van Wageningen B , Hoogerwerf N , Tan E . Near-infrared spectroscopy: a promising prehospital tool for management of traumatic brain injury. Prehosp Disaster Med. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
1

Year Published

2018
2018
2021
2021

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(29 citation statements)
references
References 17 publications
(28 reference statements)
0
26
1
Order By: Relevance
“…A study in a physician-staffed Helicopter Emergency Medical Service in Nijmegen, Netherlands, evaluated a total of 25 TBI patients. 13 There were 15 intracranial hematomas confirmed by a CT scan completed on all subjects upon arrival to a trauma center. The sensitivity in this population was 93.3%, and specificity was 78.6%.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…A study in a physician-staffed Helicopter Emergency Medical Service in Nijmegen, Netherlands, evaluated a total of 25 TBI patients. 13 There were 15 intracranial hematomas confirmed by a CT scan completed on all subjects upon arrival to a trauma center. The sensitivity in this population was 93.3%, and specificity was 78.6%.…”
Section: Resultsmentioning
confidence: 99%
“…The studies were performed with diverse age populations and locations: USA, Canada, Spain, Italy, the Netherlands, Germany, Afghanistan, Russia, Poland, India, China, and Turkey. [11][12][13][14][15][16][17][18][19][20][21][22][23] This paper outlines the development of the Infrascanner system, the first handheld device to aid in the detection of bleeding in the skull and reviews results of the clinical studies.…”
Section: Introductionmentioning
confidence: 99%
“…This 2-3 min test is specifically designed for hematoma detection in traumatic brain injury (TBI) with no data yet available for ischemic stroke. 31…”
Section: Infrared Detectionmentioning
confidence: 99%
“…More recent studies are focused upon evaluating prehospital coma gravity. For example, Peters et al [75] observed in a study including 25 patients that NIRS has a sensitivity of 93.3% and a specificity of 78.6% over CT scans in detecting intracranial hematoma.…”
Section: Near-infrared Spectroscopy (Nirs)mentioning
confidence: 99%