2018
DOI: 10.1007/s00464-018-6596-z
|View full text |Cite
|
Sign up to set email alerts
|

Near-infrared fluorescence laparoscopy of the ureter with three preclinical dyes in a pig model

Abstract: Background Ureteric injury is reported to occur in 1–7.6% of colorectal surgeries. To reduce the incidence of ureteral injury, it is essential to identify the ureters. The use of near-infrared fluorescence (NIRF) imaging with intravenously administered dyes might be of added value for ureteral visualization during laparoscopy. The aim of this study is to assess the performance of three preclinical dyes; IRDye ® 800BK, IRDye ® 800NOS and IRDye … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
27
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 28 publications
(27 citation statements)
references
References 29 publications
0
27
0
Order By: Relevance
“…Certainly, the IRDye 800BK allows for a totally non-invasive ureter visualization whereas the NICE-coated stent requires a cystoscopic placement. However, the performance of this promising dye has been described only in animal studies so far 18 , 19 , 26 . As pigs have less visceral adipose tissue than humans, their peritoneum is subsequently thinner.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Certainly, the IRDye 800BK allows for a totally non-invasive ureter visualization whereas the NICE-coated stent requires a cystoscopic placement. However, the performance of this promising dye has been described only in animal studies so far 18 , 19 , 26 . As pigs have less visceral adipose tissue than humans, their peritoneum is subsequently thinner.…”
Section: Discussionmentioning
confidence: 99%
“…The IRDye 800BK powder was diluted in a sterile phosphate-buffered saline (PBS) solution to a concentration of 1 mg/mL (as per the manufacturer’s instructions). Based on earlier studies 18 , 19 , 26 , which have achieved optimal ureteral visualization, the concentration of 0.15 mg/kg was chosen.…”
Section: Methodsmentioning
confidence: 99%
“…CW800-BK is specifically developed for visualizing the ureters, but the initial results seem comparable or even inferior to CW800-CA as lower SBRs are found. However, a recent paper found higher SBRs for CW800-BK in comparison with CW800 and newly developed 800NOS in pigs [ 40 ]. Fluorescein has a good safety profile, but its fluorescent emission is within the visible spectrum and thus high autofluorescence and low tissue penetration can be expected.…”
Section: Discussionmentioning
confidence: 99%
“…[ 40 ] Consequently, fluorophores that are renally excreted but have similar emission wavelengths to ICG at the same time are in development work is currently done preclinically in animal models. [ 41 ]…”
Section: Introductionmentioning
confidence: 99%