2006
DOI: 10.1089/pho.2006.24.730
|View full text |Cite
|
Sign up to set email alerts
|

Nd:YAG Laser Influence on Microtensile Bond Strength of Different Adhesive Systems for Human Dentin

Abstract: The application of Nd:YAG laser to dentin provided an increase in the bond strength values for the Tyrian SPE/One Step Plus and Adper Prompt L-Pop adhesive systems, but did not influence the bond strength values of the Single Bond adhesive system.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
12
0
6

Year Published

2007
2007
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(21 citation statements)
references
References 28 publications
3
12
0
6
Order By: Relevance
“…The types of failure observed in this study, by visual inspection, were predominantly adhesive for all tested groups of both substrates, which means that the cavity preparation techniques did not change the stress concentration during the test, and this finding is in accordance with previous studies that used the same self‐etching system 58, 59…”
Section: Discussionsupporting
confidence: 91%
See 1 more Smart Citation
“…The types of failure observed in this study, by visual inspection, were predominantly adhesive for all tested groups of both substrates, which means that the cavity preparation techniques did not change the stress concentration during the test, and this finding is in accordance with previous studies that used the same self‐etching system 58, 59…”
Section: Discussionsupporting
confidence: 91%
“…The types of failure observed in this study, by visual inspection, were predominantly adhesive for all tested groups of both substrates, which means that the cavity preparation techniques did not change the stress concentration during the test, and this finding is in accordance with previous studies that used the same self-etching system. 58,59 Despite the notable and unquestionable advances in dental research, there is too much to be defined concerning the ultimate effect of air abrasion or Er:YAG laser on dental substrate. Therefore, it is important that new researches be conducted to assess the adhesive/substrate interface resulting from such devices and self-etching adhesive systems, to indicate the most advisable treatment to be efficiently and safely applied in the dental practice.…”
Section: Discussionmentioning
confidence: 99%
“…30 Some studies suggest that the use of Nd:YAG laser before self-etch adhesive systems improves the bond strength due to increased availability of calcium and phosphorus after laser application. 18 However, some authors reported that when the Nd:YAG laser is applied before adhesive systems, decreased bond strength values may occur due to tubules obliteration as well as the difficulty of acid etching the melted dentin. On the other hand, increased bond strength values have been also reported when the samples are irradiated after adhesive system application and before polymerization.…”
Section: Discussionmentioning
confidence: 99%
“…Few authors hinted that the use of Nd:YAG laser before self-etch adhesive systems improves the bond strength due to increased availability of calcium and phosphorus after laser application. 18 Most authors suggested, however, that irradiation of dentin treated with either total etch or self-etch adhesive systems, prior to adhesive polymerization, could result in more stable bonding. 13,19,20 Nevertheless, the interaction between remineralizing agents containing CPP-ACP and Nd:YAG laser on dentin bond strength is unknown.…”
Section: Introductionmentioning
confidence: 99%
“…Paranhos et al determined that an Nd:YAG laser decreased the bond strength of two different adhesive systems to dentin [43]. Rolla et al reported that the application of an Nd:YAG laser to dentin provided an increase in the bond strength values of one-step self-etch adhesives [44]. However, Gürgan et al stated that an Nd:YAG laser did not impair the bond strength of adhesive systems to coronal dentin [28].…”
Section: Discussionmentioning