2007
DOI: 10.2106/00004623-200702000-00005
|View full text |Cite
|
Sign up to set email alerts
|

Navigated Total Knee Replacement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
47
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 79 publications
(47 citation statements)
references
References 38 publications
0
47
0
Order By: Relevance
“…However, Bauwens et al [18] reported that the alignment of the mechanical axes was similar in the navigation and conventional surgery groups in a metaanalysis of 33 studies. The reason for the contradictory results might rest in the implanting and/or radiographic error, which Bauwens et al [18] did not assess. Ninety-eight per cent of patients had a frontal tibiofemoral angle that was within 3°of the ideal with radiographic measurement in our study.…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…However, Bauwens et al [18] reported that the alignment of the mechanical axes was similar in the navigation and conventional surgery groups in a metaanalysis of 33 studies. The reason for the contradictory results might rest in the implanting and/or radiographic error, which Bauwens et al [18] did not assess. Ninety-eight per cent of patients had a frontal tibiofemoral angle that was within 3°of the ideal with radiographic measurement in our study.…”
Section: Discussionmentioning
confidence: 98%
“…Most studies reported more accurate alignment with fewer outliers using navigation [1,2]. However, Bauwens et al [18] reported that the alignment of the mechanical axes was similar in the navigation and conventional surgery groups in a metaanalysis of 33 studies. The reason for the contradictory results might rest in the implanting and/or radiographic error, which Bauwens et al [18] did not assess.…”
Section: Discussionmentioning
confidence: 99%
“…There are now numerous published precision studies in the literature which report on the clinical outcomes of procedures performed using a navigation system [2,15,18,20], including a recent study evaluating initial experience with EM technology [1]. The majority of cadaver and clinical studies have validated the precision of these systems in specimens or patients with normal or near normal preoperative lower limb mechanical alignment, in terms of postoperative component alignment [6,16].…”
Section: Discussionmentioning
confidence: 99%
“…There are now many published studies on various authors' experience with navigated TKA, most of which demonstrate a reduction in risk of implant malposition and more precise leg alignment when compared to conventional jig-based alignment guides [2,4,5,7,10,17,19]. However, an important distinction needs to be drawn between precision and accuracy evaluation.…”
Section: Introductionmentioning
confidence: 99%
“…Computer-assisted surgery (CAS) has become established in a number of areas of orthopaedic surgery, particularly in knee arthroplasty [1]. In sports surgery of the knee, the two main procedures for which clinical results have been published are anterior cruciate ligament (ACL) reconstruction and high tibial osteotomy (HTO).…”
Section: Introductionmentioning
confidence: 99%