Abstract:Simultaneous analysis of radionuclides in water had not been performed by mass spectrometry of the magnetic sector. Some international organizations indicate that it is necessary to know the contamination of drinking-water, including radioactive aspects. The novelty of this study was to determine simultaneously radioisotope radium, thorium, uranium and lead stable. Experiments were performed in an accredited laboratory (International Organization for Standardization/International Electrotechnical Commission-70… Show more
“…The Re VII and Re IV species have similar physicochemical properties and electrophoretic behaviour to 99 Tc and so were determined 73 by CE-ICP-MS/MS in simulated contaminated groundwater samples as stable analogues of 99 Tc. The CE-ICP-MS interface added a sheath liquid to the CE ow to increase the ow rate for ICP-MS analysis.…”
Section: Instrumental Speciationmentioning
confidence: 99%
“…The LODs were 0.01 (Re VII ) and 0.02 (total Re) mg L −1 . The authors considered this method to be a promising candidate method for monitoring 99 Tc species in contaminated groundwater.…”
Section: Instrumental Speciationmentioning
confidence: 99%
“…In the ICP-MS/MS determination of radioisotopes using a commercial high-efficiency desolvating nebuliser, the 97 Mo isobaric interference on 97 Tc was eliminated 92 by adding O 2 as a reaction gas to form MoO + and MoO 2 + . Using 97 Tc as a yield tracer for 99 Tc, the absolute LOD was 0.9 fg (0.6 mBq). In a similar procedure, the 129 Xe + isobaric interference on 129 I + decreased 93 substantially when I was reacted with O 2 and measured as 129 I 16 O + at m/z 145.…”
This review covers advances in the analysis of air, water, plants, soils and geological materials by a range of atomic spectrometric techniques including atomic emission, absorption, fluorescence and mass spectrometry.
“…The Re VII and Re IV species have similar physicochemical properties and electrophoretic behaviour to 99 Tc and so were determined 73 by CE-ICP-MS/MS in simulated contaminated groundwater samples as stable analogues of 99 Tc. The CE-ICP-MS interface added a sheath liquid to the CE ow to increase the ow rate for ICP-MS analysis.…”
Section: Instrumental Speciationmentioning
confidence: 99%
“…The LODs were 0.01 (Re VII ) and 0.02 (total Re) mg L −1 . The authors considered this method to be a promising candidate method for monitoring 99 Tc species in contaminated groundwater.…”
Section: Instrumental Speciationmentioning
confidence: 99%
“…In the ICP-MS/MS determination of radioisotopes using a commercial high-efficiency desolvating nebuliser, the 97 Mo isobaric interference on 97 Tc was eliminated 92 by adding O 2 as a reaction gas to form MoO + and MoO 2 + . Using 97 Tc as a yield tracer for 99 Tc, the absolute LOD was 0.9 fg (0.6 mBq). In a similar procedure, the 129 Xe + isobaric interference on 129 I + decreased 93 substantially when I was reacted with O 2 and measured as 129 I 16 O + at m/z 145.…”
This review covers advances in the analysis of air, water, plants, soils and geological materials by a range of atomic spectrometric techniques including atomic emission, absorption, fluorescence and mass spectrometry.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.