2021
DOI: 10.3390/pathogens10070907
|View full text |Cite
|
Sign up to set email alerts
|

Natural Infection of Dairy Cows with Bovine Leukemia Virus Affects Immunoglobulin Levels in Saliva and Serum but Not Milk

Abstract: Bovine leukemia virus (BLV) is a retroviral infection that disrupts the immune function of infected animals. It is widespread among U.S. dairy cattle. In this pilot study, the average total IgA and IgM concentrations in milk, saliva, and serum samples from BLV ELISA-positive (ELISA+) dairy cows were compared against samples from BLV ELISA-negative (ELISA−) cows using the Kruskal–Wallis test (with ties). The results from ELISA+ cows were also stratified by lymphocyte count (LC) and proviral load (PVL). In milk … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(4 citation statements)
references
References 44 publications
(60 reference statements)
0
4
0
Order By: Relevance
“…For saliva sampling, a collection polymer swab (Saliva Bio Children's Swab; Salimetrics, Carlsbad, CA, USA) was inserted through the mouth and allowed to be chewed several times to absorb saliva into the swab (Dziuba et al, 2021). Then, the swab was stored in ice‐cooled coolers for transport to the laboratory, where they were centrifuged at 1500× g for 15 min and frozen at −30°C until IgA, IgG, and albumin analyses were conducted (Dziuba et al, 2021).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…For saliva sampling, a collection polymer swab (Saliva Bio Children's Swab; Salimetrics, Carlsbad, CA, USA) was inserted through the mouth and allowed to be chewed several times to absorb saliva into the swab (Dziuba et al, 2021). Then, the swab was stored in ice‐cooled coolers for transport to the laboratory, where they were centrifuged at 1500× g for 15 min and frozen at −30°C until IgA, IgG, and albumin analyses were conducted (Dziuba et al, 2021).…”
Section: Methodsmentioning
confidence: 99%
“…Optical density values were measured at 450 nm using a microplate reader (Wallac 1420 ARVO MX; Perkin Elmer, Waltham, MA, USA) and compared with the standard curve run on each plate to determine concentrations. Samples were tested in duplicate on the same plate, and the results were averaged (Dziuba et al, 2021).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations