2016
DOI: 10.1007/s12665-016-5414-y
|View full text |Cite
|
Sign up to set email alerts
|

Natural and fallout radioactivity levels and radiation hazard evaluation in soil samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
12
0
2

Year Published

2017
2017
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(15 citation statements)
references
References 22 publications
1
12
0
2
Order By: Relevance
“…The average activity concentrations of 137 Cs were found to be 12.07 ± 0.03 Bqkg -1 , 7.55 ± 1.68 Bqkg -1 and 1.33 ± 0.6 Bqkg -1 respectively. These differences in the average activity concentration of the 137 Cs radionuclide in the soil samples in the current study confirm that the low content of clay and high content of organic matter in the soil of mountain area can be considered lead to a higher radiocaesium contamination level than at the other two locations, in addition to the transport of radiocaesium due to high amounts of rainfall in the latter two locations (Kiss et al, 1988).…”
Section: Activity Concentrationsupporting
confidence: 78%
See 1 more Smart Citation
“…The average activity concentrations of 137 Cs were found to be 12.07 ± 0.03 Bqkg -1 , 7.55 ± 1.68 Bqkg -1 and 1.33 ± 0.6 Bqkg -1 respectively. These differences in the average activity concentration of the 137 Cs radionuclide in the soil samples in the current study confirm that the low content of clay and high content of organic matter in the soil of mountain area can be considered lead to a higher radiocaesium contamination level than at the other two locations, in addition to the transport of radiocaesium due to high amounts of rainfall in the latter two locations (Kiss et al, 1988).…”
Section: Activity Concentrationsupporting
confidence: 78%
“…The graded liner comprises a 1 mm thick tin layer and a 1.5 mm thick copper layers to prevent interference by lead X-rays. To minimise scattered radiation from the shield, the detector was centred within it (Karataşlı et al, 2016). Gamma spectroscopy analysis was performed with the Genie-2000 software system interfaced with a multichannel analyser model DSA-1000, which is a full-featured 16K channel multichannel analyser with advanced digital signal processing techniques.…”
Section: Gx5020 Hpge Detection Systemmentioning
confidence: 99%
“…After getting the average of three different measurements, results were recorded in µR h -1 and then the conversion factor of 8.7 nGy µR -1 was used to change the unit of µR h -1 to the nGy h -1 . To obtain the annual effective dose equivalent (AEDE), the following equation was used [11,12].…”
Section: Determination Of Outdoor Gamma Dose Ratesmentioning
confidence: 99%
“…% 95 güvenirlik seviyesinde gama ışını ölçüm sisteminin minimum dedekte edilebilir (ölçülebilir) aktivitesi (MDA) aşağıdaki formül kullanılarak hesaplanmıştır [28,30,31].…”
Section: Aktivite öLçümüunclassified