2012 IEEE Power and Energy Society General Meeting 2012
DOI: 10.1109/pesgm.2012.6345532
|View full text |Cite
|
Sign up to set email alerts
|

NASPI<sup>[1]</sup> process applied to locate Phasor Measurement Units (PMUs) within the New York Control Area (NYCA)

Abstract: The focus of this paper is the application of the NASPI [1] generated PMU placement process to locate thirty-nine (39) Phasor Measurement Units (PMUs) within the NYCA (NYCA Study). The material for this panel paper is based upon work supported by the Department of Energy under Award Number(s) DE-OE0000368 and is a collaborative effort between the New York ISO (NYISO) and the Transmission Owners (TOs) in the NYCA.The placement of PMUs discussed in the paper follows multiple criteria with the overall objective t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2014
2014
2017
2017

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 21 publications
0
2
0
1
Order By: Relevance
“…It will rather measure only m designated channel currents, m > 0 being the threshold number. Such constraints in flow observability has been reported for several PMUs operating in the Eastern Interconnect [11]. This type of constrained observability is also relevant when one or more analog channels of a PMU start malfunctioning, or are manipulated by extraneous malicious attacks, under which conditions the measurements from those channels cannot be relied on any more.…”
Section: Pmu Placement Under Restrictions In the Number Of Channelsmentioning
confidence: 86%
See 1 more Smart Citation
“…It will rather measure only m designated channel currents, m > 0 being the threshold number. Such constraints in flow observability has been reported for several PMUs operating in the Eastern Interconnect [11]. This type of constrained observability is also relevant when one or more analog channels of a PMU start malfunctioning, or are manipulated by extraneous malicious attacks, under which conditions the measurements from those channels cannot be relied on any more.…”
Section: Pmu Placement Under Restrictions In the Number Of Channelsmentioning
confidence: 86%
“…With increase in the number of PMUs in the US grid over the past decade, placement has also been dictated by several other driving purposes such as state estimation [9], and voltage monitoring near wind power sources [10]. An illustrative case study of this problem for the New York grid has recently been presented in [11]. An excellent taxonomy of various numerical optimization methods used for solving these PMU placement problems can be found in [12].…”
Section: Introductionmentioning
confidence: 99%
“…Las herramientas o aplicaciones de un sistema de SA incluyen [28] tableros de control, monitoreo en tiempo real, control de estabilidad de frecuencia y programación de la separación de áreas si suceden ciertos eventos.…”
Section: Propuestas Con Pmus Y Conciencia Situacionalunclassified