2021
DOI: 10.1016/j.snb.2021.130553
|View full text |Cite
|
Sign up to set email alerts
|

Nanosheets-assembled hollow CdIn2S4 microspheres-based photoelectrochemical and fluorescent dual-mode aptasensor for highly sensitive assay of 17β-estradiol based on magnetic separation and enzyme catalytic amplification

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 38 publications
(15 citation statements)
references
References 44 publications
0
14
0
Order By: Relevance
“…Figure A displays the full-scan XPS spectrum, in which the peaks of Au, Cd, and S elements show up, demonstrating the formation of the Au NPs/CdS NS. As presented in Figure B, the high-resolution Cd 3d XPS section can be deconvoluted into two peaks at 412.1 and 405.4 eV, attributing to Cd 3d 5/2 and Cd 3d 3/2 of Cd 2+ species in CdS, respectively . The two separate peaks at 161.4 and 162.4 eV in the S 2p XPS part (Figure C) correlate to the doublet of S 2p 3/2 and S 2p 1/2 , respectively, which indicate the main existence of S 2– species .…”
Section: Resultsmentioning
confidence: 90%
See 1 more Smart Citation
“…Figure A displays the full-scan XPS spectrum, in which the peaks of Au, Cd, and S elements show up, demonstrating the formation of the Au NPs/CdS NS. As presented in Figure B, the high-resolution Cd 3d XPS section can be deconvoluted into two peaks at 412.1 and 405.4 eV, attributing to Cd 3d 5/2 and Cd 3d 3/2 of Cd 2+ species in CdS, respectively . The two separate peaks at 161.4 and 162.4 eV in the S 2p XPS part (Figure C) correlate to the doublet of S 2p 3/2 and S 2p 1/2 , respectively, which indicate the main existence of S 2– species .…”
Section: Resultsmentioning
confidence: 90%
“…As presented in Figure 3B, the highresolution Cd 3d XPS section can be deconvoluted into two peaks at 412.1 and 405.4 eV, attributing to Cd 3d 5/2 and Cd 3d 3/2 of Cd 2+ species in CdS, respectively. 29 The two separate peaks at 161.4 and 162.4 eV in the S 2p XPS part (Figure 3C) correlate to the doublet of S 2p 3/2 and S 2p 1/2 , respectively, which indicate the main existence of S 2− species. 25 As for the deconvoluted Au 4d XPS section (Figure 3D), two peaks centered at 83.9 and 87.6 eV are allocated to Au 4f 5/2 and Au 4f 7/2 , respectively, indicating the formation of metallic Au.…”
Section: ■ Results and Discussionmentioning
confidence: 92%
“…Typically, CdIn 2 S 4 /In 2 S 3 was synthesized under hydrothermal treatment according to previous research with minor modifications . In brief, CdIn 2 S 4 was initially prepared by dissolving 39 mg of CdCl 2 , 94 mg of InCl 3 , and 66 mg of thioacetamide (TAA) into 20 mL of water under stirring.…”
Section: Methodsmentioning
confidence: 99%
“…In recent years, ternary metal sulfides (e.g., CdIn 2 S 4 , ZnIn 2 S 4 , CuIn 2 S 4 , and FeIn 2 S 4 ) have received widespread interest for PEC systems, due to their appealing PEC properties . Among them, CdIn 2 S 4 stands out for its suitable band gap, excellent structural constancy and wide visible light responses …”
Section: Introductionmentioning
confidence: 99%
“…Compared with single-mode PEC bioanalysis, PEC-involved dual-mode bioanalysis permits cross-checking within two signals and has drawn increasing interest among the community. , Owing to the separate signaling with different mechanisms, the two signals in dual-mode detection are independent and could be mutually corroborated, which effectively improves the reliability of the analysis. In view of the advantages of dual-mode detection, a variety of PEC-involved dual-mode biosensors have been constructed, such as PEC–electrochemistry, PEC–colorimetric, and PEC–FL. Despite the superiority of these studies, the PEC-involved dual-mode bioanalysis is still in its infancy due to its short development time. The difficulty of achieving such dual-mode detections lies in the design of appropriate signal reporting systems with dual transduction routes.…”
Section: Introductionmentioning
confidence: 99%