Nanoscale Intelligent Imaging Based on Real-Time Analysis of Approach Curve by Scanning Electrochemical Microscopy

Abstract: Scanning electrochemical microscopy (SECM) enables high-resolution imaging by examining the amperometric response of an ultramicroelectrode tip near a substrate. Spatial resolution, however, is compromised for non-flat substrates, where distances from a tip far exceed the tip size to avoid artifacts caused by the tip-substrate contact. Herein, we propose a new imaging mode of SECM based on real-time analysis of approach curve to actively control nanoscale tip-substrate distances without contact. The power of t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
14
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
2
2
1

Relationship

1
4

Authors

Journals

citations
Cited by 9 publications
(14 citation statements)
references
References 43 publications
(106 reference statements)
0
14
0
Order By: Relevance
“…A home-built SECM instrument was equipped with a potentiostat (CHI 802D, CH Instruments, Austin, TX) and controlled by using the LabVIEW program based on a custom fuzzy logic algorithm as reported previously . In addition, an SECM stage was accommodated in an isothermal chamber equipped with heat sinks and vacuum insulation plates to minimize thermal drift .…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…A home-built SECM instrument was equipped with a potentiostat (CHI 802D, CH Instruments, Austin, TX) and controlled by using the LabVIEW program based on a custom fuzzy logic algorithm as reported previously . In addition, an SECM stage was accommodated in an isothermal chamber equipped with heat sinks and vacuum insulation plates to minimize thermal drift .…”
Section: Methodsmentioning
confidence: 99%
“…In addition, an SECM stage was accommodated in an isothermal chamber equipped with heat sinks and vacuum insulation plates to minimize thermal drift . Pt tips were fabricated by laser-assisted pulling, heat annealing, and focused-ion-beam (FIB) milling and characterized by SEM before and after the use for SECM experiments to check the damage to the tips . The tips were protected from electrostatic discharge as described in the Supporting Information.…”