2008
DOI: 10.1016/j.jnucmat.2008.03.018
|View full text |Cite
|
Sign up to set email alerts
|

Nanoscale characterization of HT-9 exposed to lead bismuth eutectic at 550°C for 3000h

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 18 publications
(15 citation statements)
references
References 10 publications
0
15
0
Order By: Relevance
“…The AFM technique applied in this report was developed in 1980s. Hosemann reported the application of AFM, MFM [5] and C-AFM [9] techniques to ferritic/martensitic (HT-9) and austenitic (D9) steel samples corroded in LBE. C-AFM is a contact-mode electrical characterization technique between the conductive AFM tip and the sample surface, by which variations in the local electrical properties are monitored in a range of pA to lA.…”
Section: Spm Analysesmentioning
confidence: 99%
“…The AFM technique applied in this report was developed in 1980s. Hosemann reported the application of AFM, MFM [5] and C-AFM [9] techniques to ferritic/martensitic (HT-9) and austenitic (D9) steel samples corroded in LBE. C-AFM is a contact-mode electrical characterization technique between the conductive AFM tip and the sample surface, by which variations in the local electrical properties are monitored in a range of pA to lA.…”
Section: Spm Analysesmentioning
confidence: 99%
“…By carefully controlling the oxygen concentration in the LBE coolant, it is possible to maintain an iron and chromium based oxide film on the structural surfaces while keeping lead and bismuth from excessive oxidization that can lead to precipitation contamination. HT-9 (e.g., [51,52] ), T-91 (e.g., [53,54] ), T-410 (e.g., [51,55] ), and EP823 (e.g., [53] ). [34] The oxygen control technology has been well developed, including the control method (e.g., [37][38][39] ) and oxygen concentration measurement (e.g., [39][40][41] ).…”
Section: Lbe Corrosionmentioning
confidence: 99%
“…The entire tensile sample has an activity of 7.6×10 7 Bq, leading to volumetric activity rate of 2.49×10 9 Bq/cm 3 . A rather large FIB machined LEAP sample is a cone with a 3 μm height, 1 μm base diameter and volume of 0.785× 10 −12 cm 3 .…”
Section: Dose Rate and Isotope Estimations On The Stip Samplesmentioning
confidence: 99%
“…HT-9 is considered for in core structural components in the USA because of its substantial dataset on radiation induced property changes [2][3][4][5]. In addition, the performance of HT-9 in contact with lead bismuth eutectic coolants has been examined in relevant fast reactors environments [6,7]. After the actual STIP irradiation the samples were stored for a period of 62 month in order to allow for a decay of the shorter lived isotopes.…”
Section: Introductionmentioning
confidence: 99%