2019
DOI: 10.1039/c9ra04152d
|View full text |Cite
|
Sign up to set email alerts
|

Nanoporous MIL-101(Cr) as a sensing layer coated on a quartz crystal microbalance (QCM) nanosensor to detect volatile organic compounds (VOCs)

Abstract: Metal–organic frameworks can be used as sensing layer in QCM fabrication because of their huge surface area.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
38
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 80 publications
(41 citation statements)
references
References 67 publications
2
38
0
1
Order By: Relevance
“…The peaks at 1385 and 810 cm −1 correspond C–N stretching and bending of triazines ring in melamine, respectively. The C–H vibration peaks at 749 and 579 cm −1 are attributed to benzene ring of MIL‐101(Cr) [31] indicate the MIL‐101(Cr) was successfully modified on the foam.…”
Section: Resultsmentioning
confidence: 99%
“…The peaks at 1385 and 810 cm −1 correspond C–N stretching and bending of triazines ring in melamine, respectively. The C–H vibration peaks at 749 and 579 cm −1 are attributed to benzene ring of MIL‐101(Cr) [31] indicate the MIL‐101(Cr) was successfully modified on the foam.…”
Section: Resultsmentioning
confidence: 99%
“…Quartz crystal microbalance (QCM) sensors and piezoelectric sensors based on MOFs have been also developed for detection of small organic molecules (e.g., MeOH, EtOH, MeCN, Me 2 CO). For example, KAUST-7 (NbOFFIVE-1-Ni) and KAUST-8 (AlFFIVE-1-Ni) were used for a QCM sensor for SO 2 , a Cu-BTC/polyaniline nanocomposite for a QCM-based hydrogen sensor, and MIL-101(Cr) for a QCM-based pyridine sensor [ 162 , 163 , 164 ]. The MOF [Mn 5 (NH 2 bdc) 5 (bimb) 5 ]·(H 2 O) 0.5 (NH 2 bdcH 2 = 2-amino-1,4-benzene dicarboxylic acid, bimb = 4,4′-bis(1-imidazolyl)biphenyl) displays typical ferroelectric behavior, suggesting that MOFs can be potentially applied for the construction of piezoelectric sensors [ 165 ].…”
Section: Applications Of Mofsmentioning
confidence: 99%
“…Daha sonra, temizlenmiş olan QCM kristalinin yüzeyi K[4]MR çözeltisi ile damlatma yöntemi kullanılarak kaplandı ve çözücünün buharlaşması sağlanarak kristal yüzeyinde film oluşumu gerçekleştirildi (Şekil 2B). QCM sensör filminin kaplama frekansı, film oluşumu öncesi ve sonrasındaki oluşan frekans farkından 10 kHz olarak belirlendi [20]. Böylece, K[4]MR kaplı QCM sensörün benzen, toluen ve ksilen (BTK) gibi UOB'lere karşı algılama özelliği incelendi.…”
Section: Qcm Filmin Hazırlanmasıunclassified