2020
DOI: 10.1021/acs.analchem.9b05289
|View full text |Cite
|
Sign up to set email alerts
|

Nanochannel Templated Iridium Oxide Nanostructures for Wide-Range pH Sensing from Solutions to Human Skin Surface

Abstract: Herein we report the fabrication of highly sensitive solid-state pH sensors based on iridium oxide nanowires (IONWs) for a wide-range of pH measurements. IONWs were confined electrodeposits on the indium tin oxide (ITO) electrode using a highly ordered silica nanochannel membrane as the template. Subsequently removing the template produced amorphous IONWs consisting of hydrated iridium oxyhydroxides. The IONW/ITO sensor can rapidly respond to the pH of the aqueous solutions in a wide range (from 0 to 13), avoi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0
2

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 20 publications
(16 citation statements)
references
References 52 publications
0
14
0
2
Order By: Relevance
“…The electrodes were calibrated in pH 7.0 solution (Aldrich Sigma, USA) for 2 days to stabilize the potential readings. The pH values are calculated by Nernst equation which is extensively reported in previous papers [9, 10, 14]. In ISFET sensor, pH values are displayed directly through the computer-connected interface electronics to drive the sensor and read the sensor output, provided by Microsens.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The electrodes were calibrated in pH 7.0 solution (Aldrich Sigma, USA) for 2 days to stabilize the potential readings. The pH values are calculated by Nernst equation which is extensively reported in previous papers [9, 10, 14]. In ISFET sensor, pH values are displayed directly through the computer-connected interface electronics to drive the sensor and read the sensor output, provided by Microsens.…”
Section: Methodsmentioning
confidence: 99%
“…The sensing H + on ion-sensitive field-effect transistors (ISFET) has become the standard indicator for rapid detection [6], quantification [2], and DNA sequencing [7], which means that H + from NA amplification is a reliable indicator to detect pathogens. While the metal oxide pH sensors have been used to detect pH of blood [8], skin [9], and urine [10], the sensors have not been explored as a reliable platform to detect H + from NA amplification. Recently, a label-free and electrochemical detection of NA based on primer-generation rolling circle amplification were developed on the iridium oxide pH sensor [11].…”
Section: Introductionmentioning
confidence: 99%
“…其中, 玻璃电极被 广泛应用于水溶液的pH检测, 但是, 玻璃电极存在体 积较大、质子敏感玻璃膜易损坏等缺点, 不适用于食 品、植物组织内的pH检测 [10,11] . 近年来, 离子敏感的 金属/金属氧化物, 例如二氧化钌(RuO 2 ) [12] 、五氧化二 钽(Ta 2 O 5 ) [13] 、氧化锡(SnO 2 ) [14] 、二氧化钛(TiO 2 ) [15] 、 氧化铱(IrO x ) [16,17] 等在pH检测领域得到了广泛的关注.…”
Section: 引言unclassified
“…传感器. 固态pH传感器无需内充电解液、体积灵活可 控、可微型化和柔性化 [8,16] , 在食品安全、疾病诊断 及环境保护等领域受到广泛关注 [9] . 例如, Cao等 氧化铱修饰在柔性基底表面, 结合无线数据传输技术, 构建的可植入式pH传感器用于胃食管反流患者病情 监测.…”
Section: 金属/金属氧化物可以被修饰在不同类型的基底电极 表面(包括柔性电极和微电极)制成不同类型的固态Phunclassified
“…Among the above-mentioned methods for preparing iridium electrode, the traditional electrodeposition method requires complex deposition solution with strict ratio. 32,33 Thermal oxidation and thermal sputtering require high-temperature oxidation instruments, 34,35 which are generally expensive, further limiting the application of iridium-based electrodes. In this study, the bulk iridium electrode using simple self-electrodeposition approach was prepared by cyclic voltammetry (CV) technology, which has the advantages of cost effectiveness, simple preparation, and good response performance.…”
mentioning
confidence: 99%