Abstract: We have developed an easy route to prepare (nano-ZrO2,nano-ZrCx)@C composites with varying ZrO2/ZrCx content. The process consists of preparing a zirconium-loaded, iminodiacetate-functionalized styrene-divinylbenzene (STY-DVB) copolymer, and its subsequent carbonization in a tube furnace and/or a thermal plasma reactor. Depending on the zirconium salt used (zirconyl chloride, zirconyl nitrate or zirconium (IV) sulfate) in the Zr loading, the Zr-loaded resins resulted in ZrO2@C pre-pyrolizates with C to Zr mola… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 42 publications
0
5
0
Order By: Relevance
“…Powder X-ray tests were performed with a Philips PW-1050 Bragg-Brentano parafocusing goniometer equipped with a copper cathode (40 kV, 35 mA, secondary beam graphite monochromator, proportional counter). Scans were recorded in step mode, and the diffraction patterns were evaluated with a full profile fitting technique [34,35].…”
Section: Powder X-ray Diffractometrymentioning
confidence: 99%
“…Powder X-ray tests were performed with a Philips PW-1050 Bragg-Brentano parafocusing goniometer equipped with a copper cathode (40 kV, 35 mA, secondary beam graphite monochromator, proportional counter). Scans were recorded in step mode, and the diffraction patterns were evaluated with a full profile fitting technique [34,35].…”
Section: Powder X-ray Diffractometrymentioning
confidence: 99%
“…Thermogravimetric analysis, differential scanning calorimetry, and mass spectrometric evolved gas analysis were performed simultaneously with the use of the SETARAM Labsys Evo (Lyon, France) and the Pfeiffer Vacuum OmniStar (Asslar, Germany) instruments under a He atmosphere (heating rate 20 • C/min, 25-1000 • C). The details of the thermal analysis were given in [5,6].…”
Section: Thermal Studiesmentioning
confidence: 99%
“…Therefore, a correction with the use of the amorphous carbon/graphite ratio was used (from the Raman data) in our estimations. The ratio of crystalline phases was estimated with XRD as given in [5,6]. The size of ZrO 2 and ZrC crystallites were determined by the Scherrer method.…”
Section: Powder X-ray Diffractionmentioning
confidence: 99%
See 2 more Smart Citations