1996
DOI: 10.1097/00005373-199606000-00020
|View full text |Cite
|
Sign up to set email alerts
|

Nailing Versus Plating in Thoracic Trauma

Abstract: In this study, femoral intramedullary pressure, fat embolization, and pulmonary response were measured during reamed and unreamed nailing and plating of femoral fractures after blunt thoracic trauma. Intramedullary peak pressures of 425 mm Hg (mean 205 mm Hg) occurred in the reamed nail group (group I) during reaming with the 9-mm reamer, while in the unreamed nail group (group II) peak values were seen during nail insertion (330 mm Hg) with a mean of 203 mm Hg. Plating never led to a pressure rise over 67 mm … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
31
0
2

Year Published

1997
1997
2016
2016

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 62 publications
(36 citation statements)
references
References 9 publications
3
31
0
2
Order By: Relevance
“…This model allowed for comparison to humans owing to the anatomic and physiological comparability of the lung 20 and the dimensions of the skeleton 21 and also for comparison with other studies. [22][23][24][25][26] Because most available enzymatic test kits are not suitable for sheep's blood, we decided to conduct the present experiments with pigs. Most of the clinically established physiological coagulation tests are crossreactive with this species, and a certain number of comparative studies also exist.…”
Section: Discussionmentioning
confidence: 99%
“…This model allowed for comparison to humans owing to the anatomic and physiological comparability of the lung 20 and the dimensions of the skeleton 21 and also for comparison with other studies. [22][23][24][25][26] Because most available enzymatic test kits are not suitable for sheep's blood, we decided to conduct the present experiments with pigs. Most of the clinically established physiological coagulation tests are crossreactive with this species, and a certain number of comparative studies also exist.…”
Section: Discussionmentioning
confidence: 99%
“…The normal marrow pressure is 30±50 mmHg but can be increased up to 600 mmHg during intramedullary reaming [58]. Intramedullary devices are associated with higher pressures within the marrow cavity and more FE than extramedullary fixation [59,60]. Ultrasonographically, most emboli occur during opening and manipulation of the intramedullary cavity [61].…”
Section: Infloating Theorymentioning
confidence: 99%
“…Surgical fixation of fractures increases intramedullary pressure and causes mobilisation of marrow fat [60]. The relationship between intramedullary pressure and FE has led to the development of specific strategies in trauma surgery [90].…”
Section: Surgical Strategies For Preventing Fesmentioning
confidence: 99%
“…A greater amount of bone dust may enter the vessels at insertion of femoral component because some reports indicated that intramedullary pressure 10 increased more by using bone cement [5,15,16]. At relocation of hip joint, some bone dust accumulated in the leg vein [6] may have been released and then flowed into RA.…”
Section: Discussionmentioning
confidence: 99%