2000
DOI: 10.1042/cs0980321
|View full text |Cite
|
Sign up to set email alerts
|

Myocardial tissue oxygen supply and utilization during coronary artery bypass surgery: evidence of microvascular no-reflow

Abstract: The supply and utilization of oxygen by the myocardium reflect the dynamic efficiency of the microcirculation. The present study examines these parameters during coronary artery bypass surgery. We used a voltammetric microelectrode technique to assess regional variations in myocardial tissue partial pressure of oxygen (PO(2)) and myocardial tissue perfusion (MTP) in patients undergoing coronary artery bypass surgery. A total of 29 myocardial regions were studied in 17 patients to assay tissue PO(2), and 13 reg… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
3
0

Year Published

2003
2003
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 15 publications
(18 reference statements)
2
3
0
Order By: Relevance
“…Here we showed that RV pO 2 was more than twofold higher than LV pO 2 (32 ± 5 mmHg and 15 ± 8 mmHg, respectively) in control rats. These values for LV are within the ranges reported by other authors and obtained using different methods: 45 mmHg in the LV of humans undergoing bypass surgery using voltammetric microelectrode technique 19 , 35 mmHg of mitochondrial O 2 in the rat LV 20 , 10 mmHg in the rat LV 21 and 8.6 mmHg in the swine LV using electron paramagnetic resonance oximetry 22 . These results indicate that LV pO 2 values in the literature vary considerably and are probably method-dependent.…”
Section: Discussionsupporting
confidence: 88%
“…Here we showed that RV pO 2 was more than twofold higher than LV pO 2 (32 ± 5 mmHg and 15 ± 8 mmHg, respectively) in control rats. These values for LV are within the ranges reported by other authors and obtained using different methods: 45 mmHg in the LV of humans undergoing bypass surgery using voltammetric microelectrode technique 19 , 35 mmHg of mitochondrial O 2 in the rat LV 20 , 10 mmHg in the rat LV 21 and 8.6 mmHg in the swine LV using electron paramagnetic resonance oximetry 22 . These results indicate that LV pO 2 values in the literature vary considerably and are probably method-dependent.…”
Section: Discussionsupporting
confidence: 88%
“…Here we showed that RV pO 2 was more than 2-fold higher than LV pO 2 (32±5 mmHg and 15±8 mmHg, respectively) in control rats. These values for LV are within the ranges reported by other authors and obtained using different methods: 45 mmHg in the LV of humans undergoing bypass surgery using voltammetric microelectrode technique [19], 35 mmHg of mitochondrial O 2 in the rat LV [20], 10 mmHg in the rat LV [21] and 8.6 mmHg in the swine LV using electron paramagnetic resonance oximetry [22]. These results indicate that LV pO 2 values in the literature vary considerably and are probably method-dependent.…”
Section: Rv Myocardial Oxygen Contentsupporting
confidence: 86%
“…1 However, in a subset of patients with viable myocardial tissues in the peri-infarct zone, studies have clearly shown that revascularization procedures such as coronary artery bypass grafts and coronary angioplasty increase left ventricular ejection fractions and improve survival in those patients. 2,3 Clearly, identification of such patients will be important for disease management.…”
mentioning
confidence: 99%