2023
DOI: 10.1021/acsami.2c18097
|View full text |Cite
|
Sign up to set email alerts
|

MXene/SnS2 Heterojunction for Detecting Sub-ppm NH3 at Room Temperature

Abstract: Detection of ultralow concentrations of ammonia is very important in many applications such as fishing, poultry, agriculture, industry, biomedicine, and clinical diagnosis. However, detecting sub-ppm NH3 remains a challenge for chemiresistive-type gas sensors. Two-dimensional (2D) materials display tremendous potential for effective gas detectors that can be used in these applications. The as-developed MXene/SnS2 heterojunction-based chemiresistive-type sensor presents superior gas-sensing performance toward s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
20
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 38 publications
(22 citation statements)
references
References 68 publications
0
20
0
Order By: Relevance
“…In Figure S1, pure MXene possesses much lower resistance, and the MXene-based sensors show a p-type response, which is in agreement with the results in the literature. 48,49 Additionally, the response/recovery time of Au/ α-Fe 2 O 3 /Ti 3 C 2 T x MXene devices to 5 ppm NH 3 were evaluated to be 3 and 2 s, separately, suggesting that it is a high-performance ultra-fast NH 3 gas detection equipment. Gas-sensing selectivity is one of the key indicators used to judge the properties of gas-sensitive materials.…”
Section: Gas Sensing Propertiesmentioning
confidence: 99%
“…In Figure S1, pure MXene possesses much lower resistance, and the MXene-based sensors show a p-type response, which is in agreement with the results in the literature. 48,49 Additionally, the response/recovery time of Au/ α-Fe 2 O 3 /Ti 3 C 2 T x MXene devices to 5 ppm NH 3 were evaluated to be 3 and 2 s, separately, suggesting that it is a high-performance ultra-fast NH 3 gas detection equipment. Gas-sensing selectivity is one of the key indicators used to judge the properties of gas-sensitive materials.…”
Section: Gas Sensing Propertiesmentioning
confidence: 99%
“…This slurry is dried under ambient conditions and the composite is obtained in a powder form. 89 In both the synthesis procedures above, the ratio of MXenes and TMDs is better controlled as per requirement. The other way is to grow the TMC/TMD material on MXene sheets in situ via a hydrothermal route, which might give a better intercalation of TMC/TMD between MXene nanosheets.…”
Section: Recent Developments In Mxene-based Materials For Nh3 Sensorsmentioning
confidence: 99%
“…The World Health Organization (WHO) recommends that the concentration of NH 3 in the environment produced from everyday activities must be less than 35 ppm in 15 min and not more than 25 ppm in 8 h. [1][2][3] NH 3 in exhaled breath is considered as one of the crucial biomarkers for renal disease and peptic ulcers. 4 Hence, selective and sensitive determination of NH 3 gas in the range of 1-25 ppm is of prime significance for environmental monitoring, checking for safety and medicinal investigation. Moreover, for the benefit of patients, it is essential to fabricate an NH 3 sensor that can detect NH 3 at room temperature (RT) with a high response, long-term stability, and a low limit of detection.…”
Section: Introductionmentioning
confidence: 99%