2012
DOI: 10.1093/bioinformatics/bts690
|View full text |Cite
|
Sign up to set email alerts
|

Musket: a multistage k-mer spectrum-based error corrector for Illumina sequence data

Abstract: Musket is available at http://musket.sourceforge.net.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
251
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 268 publications
(251 citation statements)
references
References 29 publications
0
251
0
Order By: Relevance
“…For testing we picked data from different Illumina sequencers. We compared RECKONER and the following state-of-the-art algorithms: Ace (Sheikhizadeh and de Ridder, 2015), BFC (Li, 2015), BLESS (Heo et al, 2014), Blue (Greenfield et al, 2014), Karect (Allam et al, 2015), Lighter (Li et al, 2014), Musket (Liu et al, 2013), Pollux (Marinier et al, 2015), RACER (Ilie and Molnar, 2013), Trowel (Lim et al, 2014). We excluded from this group the popular Quake due to its poor results according to the recent studies (Heo et al, 2014;Lim et al, 2014;Liu et al, 2013;Marinier et al, 2015).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…For testing we picked data from different Illumina sequencers. We compared RECKONER and the following state-of-the-art algorithms: Ace (Sheikhizadeh and de Ridder, 2015), BFC (Li, 2015), BLESS (Heo et al, 2014), Blue (Greenfield et al, 2014), Karect (Allam et al, 2015), Lighter (Li et al, 2014), Musket (Liu et al, 2013), Pollux (Marinier et al, 2015), RACER (Ilie and Molnar, 2013), Trowel (Lim et al, 2014). We excluded from this group the popular Quake due to its poor results according to the recent studies (Heo et al, 2014;Lim et al, 2014;Liu et al, 2013;Marinier et al, 2015).…”
Section: Resultsmentioning
confidence: 99%
“…The applied method of reads generation was proposed and used in (Kelley et al, 2010) and (Liu et al, 2013). First of all, we needed to choose the expected coverage and read length.…”
Section: Simulated Data Evaluationmentioning
confidence: 99%
See 1 more Smart Citation
“…For example, in [22] the authors show a highly accurate method for NGS reads comparison. Another example may be [13] where a method eliminating outlier reads during the data filtration stage of the processing pipeline was presented. To be more precise, the reads containing unique k-mers are treated by the method as invalid and are either corrected or discarded.…”
Section: The Use Of K-mer In Biological Sequence Comparisonmentioning
confidence: 99%
“…Some papers [6,12] specifically list this as an area where error correction has a very strong and positive impact. Finally, the short reads alignment is also improved after error correction [13,14,15,16]. Variant calling is an application of NGS directly related to alignment.…”
Section: Motivationmentioning
confidence: 99%