Multiscale Fusion Simulation of the Influence of Temperature on the Partial Discharge Signal of GIS Insulation Void Defects

Abstract: Gas insulated switchgear (GIS) in service may tolerate large temperature changes, which leads to uncertainty in the evaluation of the partial discharge (PD) signal. To clarify the influence of temperature on the discharge signals of GIS insulation void defects, this paper proposes a multiscale fusion simulation method and used experiments to verify it. This method combines the streamer simulation at the micro level and the circuit simulation model at the macro level, and a more accurate simulation signal of GI… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
1
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(3 citation statements)
references
References 19 publications
0
1
0
Order By: Relevance
“…The phenomenon that the discharge amplitude increases with phase in the half cycle of AC voltage in the spectrum is also related to the recovery effect caused by residual positive ions in the streamer channel after discharge [12]. In addition, according to literature [13], there are obvious differences in the morphology of the positive and negative half cycle discharge channels along the surface discharge.…”
Section: Discharge Energy Analysismentioning
confidence: 95%
“…The phenomenon that the discharge amplitude increases with phase in the half cycle of AC voltage in the spectrum is also related to the recovery effect caused by residual positive ions in the streamer channel after discharge [12]. In addition, according to literature [13], there are obvious differences in the morphology of the positive and negative half cycle discharge channels along the surface discharge.…”
Section: Discharge Energy Analysismentioning
confidence: 95%
“…๐ธ โƒ— ๐‘  (๐‘ง, ๐‘ก) = ๐ด ๐‘  (๐‘ง, ๐‘ก)๐‘’ ๐‘—(โˆ’๐‘˜ ๐‘  ๐‘งโˆ’๐œ” ๐‘  ๐‘ก) + ๐‘๐‘ (10) Similarly, the equation for the fluctuation of the sound field on the density distribution of the medium material is:…”
Section: Stimulated Brillouin Scatteringmentioning
confidence: 99%
“…Generally, a partial discharge aura will appear before the fault occurs in GIL [7]- [8]. In some special cases, the partial discharge phenomenon may last for months or even longer, and each occurrence of partial discharge will cause a certain degree of damage to the equipment insulation, this damage keeps accumulating and eventually leads to complete damage to electrical equipment [9]- [10].…”
Section: Introductionmentioning
confidence: 99%