2011
DOI: 10.1002/cyto.a.21009
|View full text |Cite
|
Sign up to set email alerts
|

Multiplex assessment of non‐organ‐specific autoantibodies with a novel microbead‐based immunoassay

Abstract: Advances in immunofluorescence assay development paved the way for the simultaneous detection of several antibodies in one sample, for the serological diagnosis of systemic rheumatic diseases. Standardized automated screening of such antibodies can be achieved by HEp-2 cell-based indirect immunofluorescence (IIF) using a multicolor fluorescence imaging technical platform. To create a common platform for both screening and specific antibody assessment, multiplex measurement of antibodies using fluorescence-code… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
26
0
3

Year Published

2011
2011
2017
2017

Publication Types

Select...
6
1

Relationship

4
3

Authors

Journals

citations
Cited by 34 publications
(30 citation statements)
references
References 21 publications
(21 reference statements)
1
26
0
3
Order By: Relevance
“…The VideoScan technology implemented in the Aklides system (GA Generic Assays GmbH, Dahlewitz, Germany) is a versatile fluorescence microscope imaging technology for the analysis of fluorescent objects (27,(29)(30)(31). The VideoScan instrument was automatically guided to each well of a 96-well plate, where it focused on microbeads or cell monolayer surfaces and took images, which were saved as .bmp files.…”
Section: Methodsmentioning
confidence: 99%
“…The VideoScan technology implemented in the Aklides system (GA Generic Assays GmbH, Dahlewitz, Germany) is a versatile fluorescence microscope imaging technology for the analysis of fluorescent objects (27,(29)(30)(31). The VideoScan instrument was automatically guided to each well of a 96-well plate, where it focused on microbeads or cell monolayer surfaces and took images, which were saved as .bmp files.…”
Section: Methodsmentioning
confidence: 99%
“…Fluorescent microbeads were covalently coated with SS-B, CENP-B, Sm, RNP-Sm, dsDNA, Scl-70, SS-A/Ro60, and SS-A/Ro52, respectively, as described elsewhere [21]. Further, glass slides with multi-compartment wells were employed to immobilize HEp-2 cells in the central compartment ( Figure 1).…”
Section: Multiplex Detection Of Ana By Cytobead Anamentioning
confidence: 99%
“…For semi-quantitative analysis, the intensities of the fluorescence halos can be readily detected by standard fluorescence microscopy. Instead, the signal intensity of the halo can be quantified and simultaneously located to the appropriate microbead population by digital fluorescence reading [21]. This provides the basis for automatic simultaneous interpretation of ANA on HEp-2 cells and their confirmation on antigen-coated microbeads.…”
Section: Multiplex Detection Of Ana By Cytobead Anamentioning
confidence: 99%
See 1 more Smart Citation
“…It is worth noting that this equipment is not a cytometer from its origin but has been developed as the first reliable automated system for analysis of systemic autoantibodies (4,5).…”
mentioning