2015
DOI: 10.1117/1.nph.2.1.015008
|View full text |Cite
|
Sign up to set email alerts
|

Multimodal reconstruction of microvascular-flow distributions using combined two-photon microscopy and Doppler optical coherence tomography

Abstract: Abstract. Computing microvascular cerebral blood flow (μCBF) in real cortical angiograms is challenging. Here, we investigated whether the use of Doppler optical coherence tomography (DOCT) flow measurements in individual vessel segments can help in reconstructing μCBF across the entire vasculature of a truncated cortical angiogram. A μCBF computational framework integrating DOCT measurements is presented. Simulations performed on a synthetic angiogram showed that the addition of DOCT measurements, especially … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
47
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 28 publications
(47 citation statements)
references
References 34 publications
(63 reference statements)
0
47
0
Order By: Relevance
“…The six reconstructed vascular stacks are illustrated in figure 2. Part of these stacks was previously published in Gagnon et al [39].…”
Section: (D) the Simple Heuristic Modelmentioning
confidence: 99%
“…The six reconstructed vascular stacks are illustrated in figure 2. Part of these stacks was previously published in Gagnon et al [39].…”
Section: (D) the Simple Heuristic Modelmentioning
confidence: 99%
“…The 6 angiogram constructs built in Gagnon et al [8], [21] were used as the substrates for the simulations. These constructs, referred here as Ai, i=1,…,6, were derived from measurements in the mouse somatosensory cortex using two-photon microscopy (2PH) and optical coherence tomography (OCT).…”
Section: Methodsmentioning
confidence: 99%
“…They were stored as volumes (3-dimensional arrays) with 1 μm isotropic resolution. Their total volumes were 0.27 ± 0.05 mm 3 (see [8], [21] for details). The vessel type (artery, vein, capillary) as well as oxygen saturation were provided by experimental measurements with a PO 2 sensitive molecular probe for these angiograms [6], [22].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In this paper, we aim to solely study the effect of fractional flow rate on plasma skimming. For this reason, same hematocrit cut-off conditions are applied to [28,29]. Also, relative hematocrit distribution along with vessel diameters at the microvascular network model.…”
mentioning
confidence: 99%