2021
DOI: 10.11591/ijpeds.v12.i1.pp314-324
|View full text |Cite
|
Sign up to set email alerts
|

Multilevel level single phase inverter implementation for reduced harmonic contents

Abstract: <p>Selective harmonic elimination technique SHE is adopted in this work to reduce the harmonic contents in single phase cascaded multilevel inverter. The firing instants for the electronic switches MOSFETs in the inverter are calculated off line for five level to thirteen level inverter. An Arduino microcontroller is programmed to cope with different topologies of the multilevel inverter. The implemented multi-level (MLI) inverter results are compared with Simulink simulation program and are found very c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…Seven insulated gate bipolar transistor (IGBT) switches with antiparallel diodes are utilized in the topology. The capacitor value is chosen 2200 µF with minimum voltage ripple consideration [22]. The proficiency of control techniques verified by applying SHE-PWM control using CSA.…”
Section: Simulation Results Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…Seven insulated gate bipolar transistor (IGBT) switches with antiparallel diodes are utilized in the topology. The capacitor value is chosen 2200 µF with minimum voltage ripple consideration [22]. The proficiency of control techniques verified by applying SHE-PWM control using CSA.…”
Section: Simulation Results Analysismentioning
confidence: 99%
“…An improved genetic algorithm-based control in [21] is applied for an asymmetrical 9-level inverter to suppress the 5 th , 7 th , and 11 th -order harmonics. The fundamental frequency SHE scheme has been compared with a high-frequency pulse-width modulation scheme in [22]. Tests are carried out on the 7-level inverter to justify the advantages of the SHE schemes.…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore in 2021 [21], a detailed survey on MLI such as symmetric, asymmetric, hybrid and modularized were introduced in order to generate 81-level. Besides reducing number of switches, reducing the number of harmonics at the output of inverters are of great importance [22]- [24].…”
Section: Introductionmentioning
confidence: 99%