2004
DOI: 10.1016/j.aca.2004.07.053
|View full text |Cite
|
Sign up to set email alerts
|

Multilayered construction of glucose oxidase on gold electrodes based on layer-by-layer covalent attachment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
34
0
1

Year Published

2005
2005
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 51 publications
(35 citation statements)
references
References 28 publications
0
34
0
1
Order By: Relevance
“…The sensitivity of the GOx-modified porous gold nanowire-array electrode is about 15.6 mA cm À2 mm À1 , which is higher than 5.11 and and similar to 15.1 mA cm À2 mm À1 for GOx-modified gold electrodes based on layer-by-layer covalent attachment. [19,44] The detection limit (dl) was calculated as dl = 3 s b /m, where s b is the standard deviation of the background current, and m the slope of the linear part of the calibration curve. [45] A detection limit of 4.6 10 À5 m can be obtained, which is in the typical range of detection limits of GOx-based biosensors.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The sensitivity of the GOx-modified porous gold nanowire-array electrode is about 15.6 mA cm À2 mm À1 , which is higher than 5.11 and and similar to 15.1 mA cm À2 mm À1 for GOx-modified gold electrodes based on layer-by-layer covalent attachment. [19,44] The detection limit (dl) was calculated as dl = 3 s b /m, where s b is the standard deviation of the background current, and m the slope of the linear part of the calibration curve. [45] A detection limit of 4.6 10 À5 m can be obtained, which is in the typical range of detection limits of GOx-based biosensors.…”
Section: Resultsmentioning
confidence: 99%
“…[45] A detection limit of 4.6 10 À5 m can be obtained, which is in the typical range of detection limits of GOx-based biosensors. [19,27,44,46] The effect of ascorbic acid was investigated by measuring the amperometric response toward 0.5 mm ascorbic acid, and the absence of observable interference at À0.1 V suggests that ascorbic acid is not electrochemically active at this potential. This result is consistent with those of previous studies.…”
Section: Resultsmentioning
confidence: 99%
“…Their bimolecular rate constants for FADH 2 -GOx oxidation range from 3 × 10 4 to 8 × 10 6 M -1 s -1 . 148 The most intensively studied ferrocene-derivatives are ferrocenemethanol 88,90,91,[149][150][151][152][153][154][155][156][157][158][159][160][161] and ferrocenecarboxylic acid. 155,[162][163][164] Several of the ferrocenes meet the requirements for application in blood-glucose analyzers, which include high solubility in water, fast electron-shuttling, stability, and pH-independence of the redox potential.…”
Section: Metal-organic Mediatorsmentioning
confidence: 99%
“…There are several reports on MeOHFc mediated biosensor (Setti et al, 2005;Piro et al, 2001;Zhang et al, 2004a). However, MeOHFc was generally added directly into the test solution, which results in many application problems.…”
Section: Resultsmentioning
confidence: 99%